THERMAL CONSIDERATIONS

THERMAL CONSIDERATIONS

Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel.

Thermal Testing Setup

Thermal Derating

Heat can be removed by increasing airflow over the module. The module’s maximum case temperature is 95. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected.

THERMAL CURVES

Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted.

The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’).

Figure 20: Temperature measurement location viewed from the

IMS side

The allowed maximum hot spot temperature is defined at 95

FACING PWB

AIR VELOCITY

AND AMBIENT

TEMPERATURE

MEASURED BELOW

THE MODULE

AIR FLOW

PWB

MODULE

50.8 (2.0”)

Thermal Testing Setup 12.7 (0.5”)

 

F48SA28025(Standard) Output Power vs. Hot Spot Temperature

Output Power (W)

(Either Orientation)

750

700

650

600

550

500

450

400

350

25

35

45

55

65

75

85

95

 

 

 

 

 

 

Hot spot Temperature()

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

Figure 19: Wind tunnel test setup

Figure 21: Output power vs. hot spot temperature (Either Orientation)

DS_F48SA28025_12072007

11

Page 11
Image 11
Delta Electronics F48SA manual Thermal Considerations, Thermal Curves, Thermal Testing Setup, Thermal Derating