Fireplace

Installation

 

Continued

Propane/LP

Equipment Shutoff Valve

Supply Tank

 

 

Gas Valve

Figure 24 - Checking Gas Joints for

Propane/LP Gas Fireplace

Equipment

Shutoff Valve

Gas

Meter

Gas Valve

Figure 25 - Checking Gas Joints for

Natural Gas Fireplace

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Fig- ure 23, page 16).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 24 or Figure

25). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, page 21). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 21).

Removing/Replacing Glass

Doors

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 24.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off fireplace. Let cool before removing glass doors.

WARNING: More than one person is required when replac- ing glass.

Models DVF-36S and DVF-36H have only an inner door to be removed/replaced. Models DVF-36SC and DVF-36HC have an inner, middle and outer door.

Installing Middle Door (DVF-36SC/HC Models Only)

Middle door hangs on 2 hinges from top of inner glass door (see Figure 26, page 18).

1.Remove middle door from packaging.

2.Angle middle door so top goes into fireplace first. Hang middle door on brackets at top of inner door (see Figure 26, page 18).

Installing Outer Door (DVF-36SC/HC Models Only)

1.Remove outer door from packaging.

2.There are three spring loaded pins on outer door. Set pins to the locked position

(see Figure 26, page 18).

3.Position outer door so pins line up with mating hinges on fireplace. Holding door in place, release locks on spring loaded pins (see Figure 26, page 18).

120441-01A

www.desatech.com

17

Page 17
Image 17
Design Dynamics DVF-36S-N Removing/Replacing Glass Doors, Pressure Testing Fireplace Gas Connections