www.desatech.com 120441-01A24

WARNING: Do not operate re-

place with glass door unlatched,

removed, cracked or broken.

PILOT AND BURNERS

• Remove material before cleaning burners
and replace when cleaning is complete.
• Burner and controls should be cleaned
with compressed air to remove dust, dirt
or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.

LOGS

• Use a vacuum cleaner to remove any
carbon buildup on logs.
• Replace material periodically as needed.
See Replacement Parts.

VENTING SYSTEM

Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualied service person.
2. Remove the vent cap and shine a ash-
light into the vent. Remove any foreign
material.
3. Check for evidence of excessive con-
densation. Continuous condensation can
cause corrosion of caps, pipes and ttings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section
or tting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.
technicAL Service
You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact DESA’s Customer Service Depart-
ment at 1-866-672-6040. When calling, please
have your model and serial numbers of your
heater ready.
You can also visit DESA’s technical service
web site at www.desatech.com.
cLeAninG AnD MAintenAnce
Continued
SPeciFicAtiOnS
DVF-36S-N, DVF-36H-N, DVF-36SC-N,
DVF-36HC-N
• Rating: 66,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 7.0" w.c.
DVF-36S-P, DVF-36H_P, DVF-36SC-P,
DVF-36SH-P
• Rating: 62,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10.0" w.c.
• Minimum Inlet Supply Pressure: 11.0" w.c.
rePLAceMent PArtS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.

pARTS UNDER WARRANTY

Contact authorized retailers of this product.
If they can not supply original replacement
part(s), call DESA’s Customer Service Depart-
ment at 1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your re-
place
• how replace was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the part to
the factory.

pARTS NOT UNDER WARRANTY

Contact authorized retailers of this product.
If they can not supply original replacement
part(s), call DESA at 1-866-672-6040 for
referral information.
When calling DESA, have ready
• model number of your replace
• the replacement part number
Service hintS
When Gas pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• replace will not produce specied heat
• propane/LP gas supply might be low (pro-
pane/LP units only)
You may feel your gas pressure is too low. If
so, contact your local gas supplier.