TROUBLESHOOTING

Continued

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Pilot will not stay lit

1.

Loose wiring on ignitor wire

 

 

to ignition module and/or

 

 

poor ground to ignition

 

 

module

 

2.

Pilot flame too low to

 

 

sense

1.Check wiring connection. Refer to wiring diagram (see Wiring Diagram, page

21)and/or check ground wire to ignition module

2.Clean and adjust pilot burn- er and check gas supply and inlet pressure to unit Note: Have a qualified tech- nician replace pilot assem- bly if broken or corroded

No gas to burner, although wall

1.

Wall switch wires defective

1.

Check electrical connec-

switch and valve are set to the

 

or too long

 

tions

ON position

 

 

 

 

 

 

 

 

 

Frequent pilot outage

1.

Pilot flame may be too

1.

Clean and adjust pilot flame

 

 

low, causing safety pilot to

 

for maximum flame impinge-

 

 

“drop out”

 

ment on thermopile

 

2.

Improper venting or exces-

2.

Have the vent system in-

 

 

sive blockage

 

spected, including the ter-

 

 

 

 

mination cap. Remove any

 

 

 

 

restriction or obstruction

 

 

 

 

 

Fireplace produces a clicking/

1.

Metal expanding while

1.

This is normal with most

ticking noise just after burner

 

heating or contracting while

 

fireplaces. If noise is ex-

is lit or shut off

 

cooling

 

cessive, contact qualified

 

 

 

 

service person

 

 

 

 

 

Slight smoke or odor during

1.

Residues from manufac-

1.

Problem will stop after a few

initial operation

 

turing processes and logs

 

hours of operation

 

 

curing

 

 

26

www.desatech.com

120441-01A

Page 26
Image 26
Design Dynamics DVF-36S-N Pilot will not stay lit, To ignition module and/or, Poor ground to ignition, Module, Sense