GE RAK164D1, RAK148D1 Turns on and stage 2 turns on, Adjust to calibrate displayed room

Page 9

3. Temperature Differential—Stage 2—(RAK148D1 only) (1–9°F) (1–5°C)—Set the number of degrees between when stage 1

turns on and stage 2 turns on.

Press the < or > button to set differential value. Press the SW6 button to advance to the next screen.

4. Minimum Cool Setpoint (60, 64, 66, 68, 70, 72, 74, 76°F) (15, 17, 19, 20, 21, 22, 23, 24°C)

Adjust to control the minimum Cool set temperature allowed. Press the < or > button to select.

Press the SW6 button to advance to the next screen.

5. Maximum Heat Setpoint (65, 70, 72, 74, 76, 78, 80, 85°F) (18, 21, 22, 23, 24, 26, 27, 29°C)

Adjust to control the maximum Heat set temperature allowed. Press the < or > button to select.

Press the SW6 button to advance to the next screen.

6.Room temperature offset (+9°F to –9°F) (+5°C to –5°C)

Adjust to calibrate displayed room

temperature to match actual room temperature. Press the < or > button to select.

Press the SW6 button to advance to the next screen.

9

Image 9
Contents Thermostats Installation InstructionsSpecifications Important safety informationIntroduction Overview Thermostat Control Installation Instructions To Install Thermostat Wiring diagrams Terminals for six wires 2 heat/1 cool system RAK148D1 only Configuration Mode Settings Configuration modeSetup screens for Configuration Mode are as follows Button Press the SW6 button to advance to the next screenTurns on and stage 2 turns on Adjust to calibrate displayed roomMove the Fan Auto/On switch to the Auto position Testing the thermostatTerminal designator descriptions Starting the thermostatHeat Test Operating functionsFan Test OffTroubleshooting tips Problem SolutionHeat Page Page Page For The Period GE Will Replace Thermostat Warranty