CA8900 | 6 |
|
|
5 – Find and Use the Set-Up Diagram for Your System
Find the reference page with your wiring diagram and jumper
If your combination of wires is not shown here, you can use the Wiring Reference Guide beginning on page 11 to determine your connections, or contact Customer Service for help.
2 WIRE HEAT +C
WIRES:
C W RH
From | 2 Wire | |
Furnace | ||
|
| Heat +C |
|
| |
|
|
|
1.Connect the R (or RH) wire to the RH terminal on the CA8900. This connects the Heater Power to the thermostat.
2.Connect the W wire to the W on the CA8900. This connects the heater control line to the CA8900.
OPTIONAL POWER
C
W | RH |
|
C W R
3.Connect the C wire to the C terminal on the CA8900. This con- nects 24vac power.
4. Set Config jumpers as shown. |
|
| 1 | 2 |
| 3 4 5 | ||
A |
|
| ||||||
|
|
|
|
|
| |||
B |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Your system is now connected. Continue on page 9. |
C B O W2 W Y RH RC G A
CA8900 Terminals
3 Wire Zoned Hot Water +C
WIRES:
W RH A
From | 3 Wire |
| |
Furnace | Zoned |
| |
| Hot Water +C | ||
W | RH | A | C |
|
| Motor Valve | |
| C | W | R A |
1.Based on your valve type:
2.Connect the C wire to the C terminal on the CA8900. This con-
nects 24vac power. | 1 | 2 | 3 | 4 | 5 |
|
3. Set Config jumpers as shown.
C B O W2 W Y RH RC G A
CA8900 Terminals
Your system is now connected. Continue on page 9.
Providing a brighter solution.™