Trane CA8900 manual O W2 W Y, W2 W Y R H G

Page 8

CA8900 Z-Wave®Thermostat Installation Guide

8

4Wire Heat Pump w/o Aux +C

WIRES:

CB or

From

Furnace

C

B

O

O Y RH G

4 Wire Heat Pump w/o Aux Heat +C

Y

RH

G

 

1.Connect O wire to the O terminal or B wire to the B terminal on the CA8900. (If you have both O and B, connect O wire to O terminal

DO NOT connect B to B terminal. (See page 10 Trane for the B wire terminal.) This connects the change-over valve.

2.

Connect the Y wire to Y on the CA8900. This connects the Com-

 

pressor.

3.

Connect the R (or RH) wire to RH on the CA8900. This connects

 

to the 24vac power.

 

HEAT PUMP SYSTEM

C

OorB Y RH G

or

 

C B O W2 W Y

RH RC G A

CA8900 Terminals

 

5 Wire

WIRES:

Heat

C B or O W2 Y R H G

From

 

 

5 Wire

 

 

Pump

 

 

 

 

Furnace

 

 

Heat Pump

 

 

 

 

 

 

 

 

w/ Aux

 

 

 

 

 

 

w/ Aux Heat

Heat +C

 

 

 

 

 

 

 

 

+C

 

 

 

 

 

 

 

 

 

 

C

B

O

W2

 

Y

RH

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

HEAT PUMP SYSTEM

 

OPTIONAL POWER

C

OorB

W2

 

Y

R

G

 

 

or

 

 

 

 

 

 

 

 

 

C B O W2 W Y

 

RH RC G A

CA8900 Terminals

 

 

 

 

 

 

 

 

 

2 Stage

 

WIRES:

 

 

 

 

 

 

 

 

C W2 W Y R H G

Heat and

 

Furnace

 

 

1 stage Cool

1 Stage

 

From

 

 

 

 

 

 

 

 

 

 

 

2 stage Heat

Cool +C

 

 

 

 

 

 

 

 

+C

 

 

C

W2

W

Y

 

RH G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HVAC SYSTEM

 

 

 

C

W2

W

Y

 

 

RH

 

G

OPTIONAL

POWER

C B O W2 W Y RH RC G A

CA8900 Terminals

4.

Connect the G wire to the G terminal on the CA8900. This con-

 

nects the Fan.

5.

Connect the C wire to the C terminal on the CA8900. This con-

nects 24vac power.

1

2

3

4 5

6. Set Config jumpers as shown.

Your system is now connected. Continue on page 9.

1.Connect O wire to the O terminal or B wire to the B terminal on the CA8900. If you have both O and B, connect O wire to O terminal.

DO NOT connect B to B terminal. See page 10 Trane for B wire terminal.

2.Connect the W2 wire to W2 on the CA8900.

3.Connect the Y wire to Y on the CA8900.

4.Connect the R wire to RH on the CA8900.

5.Connect the G wire to G on the CA8900.

6.Connect the C wire to the C terminal on the CA8900. This con- nects 24vac power.

7.

Set Config jumpers as shown. 1

2 3 4 5

8.

Set jumper 5 if you have Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or Oil aux heat.

 

 

 

 

 

 

 

Your system is now connected. Continue on page 9.

1.Connect the W wire to the W terminal and W2 to W2 on the CA8900. This connects 2 stages of heat.

2.Connect the Y wire to the Y terminal wire on the CA8900. This connects cool.

3.Connect the RH or R wire to the RH terminal on the thermostat. This connects the Heater/Cool Power.

4.Connect the G wire to the G terminal on the Thermostat. This connects to the Fan.

5.Connect the C wire to the C terminal on the CA8900. This con- nects 24vac power

6. Set Config jumpers as shown.

 

 

1

 

2

 

3 4 5

 

 

 

 

 

-- If you have Electric heat, set 1A. A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-- If you have Gas or Oil, set 1B.

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Your system is now connected. Continue on page 9.

Providing a brighter solution.™

Image 8
Contents Description and Features This guide is in two partsUsing the Save Energy Button Operating the CA8900Low Battery Warning Setting a Heat Pump’s AUX only ModeJoining to a Z-WaveNetwork Displaying Fahrenheit or CelsiusLabel Wires from Old Unit Tools NeededLocation of Thermostat Remove Old UnitMount the CA8900 Thermostat Before You Connect WiresWhich wires do you have? Nects 24vac power Find and Use the Set-Up Diagram for Your SystemWire Zoned Hot Water +C Wire Heat Set Config jumpers as shownWire Heat/Cool WireO W2 W Y W2 W Y R H GInstall AA Batteries To check Heat modeTo check Cool mode Check Out the CA8900 UnitPower Requirement Wire Reference GuideYour Wires Intermatic Terminal Changing CalibrationJumper Reference Hpaux Type