6 – Install AA Batteries

While the CA8900 requires the C wire (24VAC) to operate. It also requires 2AA batteries to back-up the 24VAC power for up to a few days.

1.Install 2 AA alkaline batteries according to the polar- ity noted in the compartment. LCD segments will go on.

2.Press the RESET button (on front of the thermostat) to clear transient program memory.

NOTE: Replace the batteries when this LOW battery indicator appears on the display or once a year.

When you have finished inserting the batteries:

1.Attach control unit to wall unit.

2.Hook the top of the body onto the base.

3.Swing the body down, and

4.Snap the body onto the base.

7 – Check Out the CA8900 Unit

Follow these procedures to verify you have correctly installed the CA8900.

Turn power to the system back on.

To check Fan: (If you connected the G wire – fan relay)

1.Slide the FAN switch to the ON position.

2.Verify that air is blowing from the system.

3.Return to AUTO position for normal operation.

To check HEAT mode:

1.Press HEAT button, setting the mode to HEAT. The word HEAT displays.

2.Slide the FAN switch to AUTO.

3.Using the TEMP UP (+) button, raise the Target Temp to 90° F.

4.Allow the system 2 min to respond.

5.Verify that heat is blowing from the system.

6.Press the HEAT button to shut heat off.

To check COOL mode:

1.Press the COOL button, setting the mode to COOL. The word COOL displays.

2.Slide the FAN switch to AUTO.

+

AA

-

+

AA

-

 

 

 

COOL

TEMP UP

COOL

 

RESET

 

 

 

 

 

NORMAL SAVE

Y

HEAT

AUTO

ON

 

 

COOL

 

ENERG

 

FAN

 

 

 

 

 

TEMP

HEAT

 

 

COOL

Fan

DOWN

Button

 

Button

 

3.Press the TEMP DOWN (–)button to a temp 5 de- grees below the room temp.

4.Allow the system 2 minutes to respond.

5.Verify that cool air is blowing from the system.

6.Press the COOL button to shut cooling off.

Congratulations, you have successfully

installed your unit.

Please proceed to the OPERATING Guide

to initialize the CA8900.

NOTE: If you have labeled your wires, followed the correct Step-By-Step, and these Check procedures do not operate your system, call Customer Support.

Providing a brighter solution.™

Image 9
Contents This guide is in two parts Description and FeaturesOperating the CA8900 Using the Save Energy ButtonSetting a Heat Pump’s AUX only Mode Low Battery WarningJoining to a Z-WaveNetwork Displaying Fahrenheit or CelsiusTools Needed Label Wires from Old UnitLocation of Thermostat Remove Old UnitBefore You Connect Wires Which wires do you have?Mount the CA8900 Thermostat Find and Use the Set-Up Diagram for Your System Wire Zoned Hot Water +CNects 24vac power Set Config jumpers as shown Wire HeatWire Heat/Cool WireW2 W Y R H G O W2 W YTo check Heat mode Install AA BatteriesTo check Cool mode Check Out the CA8900 UnitWire Reference Guide Power RequirementYour Wires Intermatic Terminal Changing CalibrationHpaux Type Jumper Reference