HOLIDAY MODE -- This feature forces the thermo-

stat into Unoccupied for a preset duration, up to

99 days, The Holiday setup display is entered as follows:

oHOLIDAY ©

 

 

 

H_[

 

 

 

 

When

active

 

 

 

 

 

 

 

 

the

display

 

 

 

 

 

 

 

 

 

counts

down

 

 

 

 

 

 

 

 

remaining

days

 

 

 

 

 

PJII_I

 

Unoccupied

also

 

 

 

 

 

 

blinking,

 

@

S

 

 

 

 

 

 

appear&

 

 

Press

the

Up or

Down

buttons

to select

 

the

 

 

 

 

 

".......... -'

number

of

days

the

thermostat

will be

in

 

 

_:

)

Holiday

mode.

0 =

Off.

To exit

Holiday

 

setup,

 

 

press

the

Mode

button.

 

 

 

 

 

The thermostat will enter the Holiday mode when the clock crosses midnight.

During Holiday mode Unoccupied set points are enforced.

The Override button is active during Holiday mode. It will override to Occupied 1 settings up to 4 hours then return to Holiday mode. The Dry Contact Switch is ignored.

The thermostat will exit Holiday mode at midnight of the final programmed day. To terminate Holiday immediately, enter the Holiday setup screen and select 0.

SOFT START -- This feature is utilized in multiple thermostat installations controlled by the Dry Con- tact terminals. Assigning a unique Soft Start num- ber to each thermostat will stagger the turn on times, even though the Dry Contact closes, for all the thermostats connected, at the same time. Each Soft Start number represents a multiple of 30 sec- onds from the Dry Contact closure. For example, no. 1 = turn on 30 seconds after Dry Contact clo- sure, no. 2 = turn on 60 seconds after closure,

no. 3 = turn on 90 seconds after closure, and so on.

See page 5, Step 13, to configure the thermostat for Soft Start.

DUAL SET POINT BEHAVIOR --The adjustable set point range is: 35 to 99 degrees in Fahrenheit and 7 to 35 degrees in Celsius. When in the modes Heat or Cool, this adjustable range is unhampered.

When adjusting any Auto mode, including program- ming Occupied and Unoccupied periods, the ther- mostat will not allow the Heat set point to get closer to the Cool set point than the value programmed as the minimum difference in Step 5, page 4.

When entering the Auto mode from Cool, the Heat and Cool set points will remain spread apart by the

amount that they were adjusted, prior to entering Auto.

For example: If the Cool set point was set to 80 while in the Cool mode and the Heat set point was adjusted to 70 while in the Heat mode, upon enter- ing the Auto mode the Heat and Cool set points would be 80 and 70. Both set point temperatures would then move up and down together, (in this

example spread by 10 degrees), by pressing the up or down buttons.

To move the Heat and Cool set point temperatures closer together, enter the Cool or Heat mode by pressing the Mode button, then adjust the set point temperatures closer together. Heat is limited to how close it can come to Cool by Step 5, page 4.

REMOTE SENSORS (Optional Accessory) -- When connected to terminals RS+5, RS, and GND on the back of the thermostat, the thermostat will read the temperature from the Remote Sensor and ignore the temperature sensor inside the thermo- stat. The thermostat automatically recognizes when a Remote Sensor is connected. When reading the temperature from the remote, the degree icon above the room temperature blinks once a second.

 

 

The Override

button

 

 

on the Remote

Sensor

 

 

works slightly

different

 

 

than the Override but-

Optiona_

 

ton on the front panel.

 

Each press of the

 

 

Remote

Sensor

'External'Override but-

Optional Sensor

 

ton adds 2 hours to the

 

 

override timer,

if the

timer was already active, the first button press will round the runtime to either 2:00 or 4:00.

Subsequent button presses will not wraparound as the Override button on the thermostat does, so the second or greater button press will set the runtime to 4:00. The Locked feature has no effect on the external Override button. The wired Remote Sensor is connected to the thermostat with up to 500 ft of 20 ga. or 300 ft of 18 ga. thermostat wire. See the Remote Sensor instructions for further details.

FACTORY DEFAULTS -- Before restoring factory defaults, set thermostat to OFF mode. If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Fan button for 5 seconds. All icons will appear. Press and hold in the Fan button until Fd appears. This resets all factory settings. To calibrate room temperature, press the Up and Down buttons at the same time twice. At this point use the Up and Down buttons to calibrate room temperature, if needed. Press the Mode button to return to normal operation.

Page 6

Image 6
Contents Set the clock BeforeIMPORTANTproceeding,Follow Installation InstructionsDisplay Quick Start Occupied Unoccupied PeriodsRun. See AutoOffon See this+$t Select Occupied To run On this Day Or not to Run this OffBrn H Programming NotesSetup Minimum HEAT/COOL SET Point DifferenceWhen Active Display Counts Down Remaining Days ButtonBlinking Appear YlYl li 1 iTIi Form OM53-4

53DFS250-SL specifications

The Carrier 53DFS250-SL is a cutting-edge unit designed for efficient temperature control in commercial applications. This model stands out due to its advanced technological features and robust build quality, making it well-suited for various HVAC needs. One of the key characteristics of the Carrier 53DFS250-SL is its impressive cooling and heating capacities, which are optimized for maximum performance. The unit operates efficiently, providing a cooling capacity of 53,000 BTUs, which ensures that spaces are maintained at comfortable temperatures even in extreme conditions.

One of the noteworthy features of this model is its variable-speed compressor, which allows for precise temperature management. This technology enables the unit to adjust its output based on the current demand, reducing energy consumption while maintaining comfort. Coupled with a multi-stage filtration system, the Carrier 53DFS250-SL guarantees superior air quality, removing contaminants and allergens from the indoor environment.

Energy efficiency is a significant consideration for modern HVAC systems, and the Carrier 53DFS250-SL excels in this regard. With a high SEER (Seasonal Energy Efficiency Ratio) rating, it not only lowers utility bills but also meets or exceeds regulatory standards for energy consumption. The unit is designed with environmentally friendly refrigerants that minimize its carbon footprint, aligning with today's sustainability goals.

The Carrier 53DFS250-SL also incorporates advanced control features, including a programmable thermostat option that allows users to optimize performance based on their schedules. This feature enhances user convenience while ensuring energy savings. Additionally, the unit supports connectivity options for smart home integration, making it adaptable to modern living environments.

Durability is another hallmark of the Carrier brand, and the 53DFS250-SL is no exception. Constructed from high-quality materials, the unit is designed to withstand various weather conditions, making it a reliable solution for long-term use. Its compact design allows for flexible installation options, fitting seamlessly into a variety of architectural layouts.

In summary, the Carrier 53DFS250-SL is a powerful, efficient, and versatile HVAC solution. With its variable-speed technology, exceptional energy efficiency, and robust build quality, it is the perfect choice for those seeking reliable climate control in commercial settings. Whether cooling or heating, this unit demonstrates superior performance that can adapt to the ever-changing demands of indoor environments.