Emerson 1F97-1277 specifications Wired Remote Temperature Sensing, Weight of Remote Reading

Page 11

Wired Remote Temperature Sensing

One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 ft).. Three terminals, +, S & - are provided on the terminal block to connect to the White- Rodgers standard wired remote sensor.. This sensor will be read by the thermostat only when 24VAC is present..

When used as indoor sensor, the readings can be weighted with the local sensor for specific program periods. User can enable or disable the remote sensor in the installer configura- tion mode and also the outdoor temperature can be selected to show on the display..

Once in the installer configuration mode, momentarily press the or touch key until display indicates Remote (at the top left of the LCD) and OFF (default – in clock digits)..

Pressing or touch key will toggle the operation and display from Remote OFF to Remote On..

When Remote On is selected, press key for the display to indicate Remote In (for indoor remote)..

The or keys will toggle the operation and display from Remote In to Outdoor Remote..

When any remote is selected the temperature will display in the clock digits for one second alternating with the current time for three seconds when in Run Schedule mode.. Outdoor Remote will indicate at the top left of display for outdoor remote reading..

Only Remote will show at top left for indoor remote reading.. (oF or oC will not indicate with remote temperature readings)..

Sensing Range:

Outdoor temperature range is -40 to 140oF Indoor temperature range is 32 oF to 99 oF

PROGRAMMING

Weight of Remote Reading:

When in view schedule mode the weight of the indoor remote sensor will be shown in the left actual temperature digits des- ignated as A2 (default for average weight), H4 (high weight) or L1 (low weight).. The period (Morning, Day, Evening, Night) will also be shown to the right of the weight value in the actual temperature digits..

When in view schedule mode, press and keys at the the same time to sequence the indoor remote temperature sensor weight from A2 to H4 to L1 and back to A2 for each of the program period times for each day.. (The H4 weight is twice the weight of A2 and A2 is twice the weight of L1)..

When Remote In is selected (with Remote selected to On), press key for the display to indicate the status of the local sensor LS On (default for thermostat local sensor operation- al).. The and keys will toggle the function and display from LS (shown in actual temperature digits) and On (shown in clock digits) to LS OFF to designate the local sensor is disabled..

The local sensor may be disabled only if the indoor remote sensor is enabled and functional..

If the indoor remote sensor is disabled or not functional, the local sensor will automatically enable and display in the run schedule mode..

The actual temperature displayed in the run mode is the mathematical weighted sum of the two temperature sensors – local and indoor remote..

(Outdoor remote sensor is not used for this computation)..

If the remote sensor is absent or not enabled then the actual temperature will be as measured by the local sensor..

11

Image 11
Contents Index Installation and Operating Instructions for ModelApplications Save these instructions for future useBattery Location InstallationWiring Connections Installing New ThermostatHeat Pump Systems Single Stage ConnectionsSingle Stage System with Single Transformer Single Stage with Two TransformersHome Screen Description Programming and Configuration ItemsDisplays and Keypad Lockout when in keypad lockout mode Thermostat Quick ReferenceConfiguration Menu INSTALLER/CONFIGURATION MenuHeat Cool Emer Mode Fast rateSelections Lowered Keys to select onPress Display will read Record the number you select for future useProgramming Operating Your ThermostatEntering Fan Program Enter the Heating ProgramEnter the Cooling Program Automatic ScheduleWorksheet for Re-Programming 5+1+1 and 7 Day Program Energy Saving Factory Pre-ProgramPlanning Your Program Important Weight of Remote Reading Wired Remote Temperature SensingReset Operation TroubleshootingSymptom Possible Cause Corrective Action

1F97-1277 specifications

The Emerson 1F97-1277 is a state-of-the-art thermostat designed to deliver smart climate control for residential settings. This sleek, user-friendly device is packed with advanced features and technologies that enhance comfort while optimizing energy efficiency. Ideal for homeowners who seek seamless temperature management, the 1F97-1277 stands out in a crowded market due to its intuitive design and versatility.

One of the key features of the Emerson 1F97-1277 is its Smart Wi-Fi capability, which allows users to control their home’s heating and cooling systems remotely. By utilizing a mobile app compatible with both iOS and Android, homeowners can monitor and adjust their home temperature from virtually anywhere, whether at work or on vacation. This level of control not only enhances convenience but also ensures that homes are heated or cooled to the desired temperature before residents arrive.

Additionally, the 1F97-1277 includes Smart Home integration features, allowing it to work seamlessly with various smart home systems, including Amazon Alexa and Google Assistant. Voice control is an added convenience, making it easy to change settings or check the current temperature with just a simple command.

The thermostat also boasts a sophisticated touchscreen display, which presents a vibrant interface that simplifies navigation through its settings and options. With customizable settings, users can create schedules that align with their daily routines, thereby optimizing energy consumption and reducing utility costs. The 7-day programming feature allows for tailored comfort throughout the week, ensuring that the home is always at the desired temperature during peak hours.

Moreover, the Emerson 1F97-1277 incorporates Eco-Friendly settings, which are designed to help users reduce their carbon footprint. Its learning capabilities enable it to adapt to user preferences over time, enhancing both comfort and energy efficiency.

Finally, installation of the Emerson 1F97-1277 is straightforward, with support for both conventional and heat pump systems, making it a flexible choice for a variety of home heating and cooling applications. Its compatibility with most HVAC systems makes it a reliable solution for modern households.

In conclusion, the Emerson 1F97-1277 thermostat is an exemplary product that represents the intersection of technology and user-centric design. With its smart features, user-friendly interface, and energy-saving capabilities, it is an ideal choice for homeowners aiming to enhance their comfort and efficiency.