Aube Technologies TH116 A Technical Specifications, Service, Warranty, Slave Units Gfci Test

Page 3

3.3 Master Thermostat - Installation and Wiring

WARNING: Make sure all slave units are in STANDBY mode.

Required parts: TH113-A/F/AF (12VDC), TH114-A/F/AF (12VDC), TH115-A/F/AF (12VDC) or TH116-A/F/AF (12VDC)

Location: anywhere easily accessible to users.

Temperature control: AF (ambient with floor limit) / A (ambient)

Install the master thermostat in the controlled area.

Choose a location about 5 ft. above the floor in an area where the tempera- ture is stable.

Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.

Temperature control: F (floor)

Can be installed anywhere.

sWire the 12 VDC base to the nearest slave unit.

The floor sensor must be installed in an area where average temperature can be read. The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire.

For maximum performance, the sensor probe should be centered between the wires in the mat (max. 80°C).

tPush the excess wire into the wall, secure the base using the provided screws and wall anchors, and install the TH11x thermostat onto the base.

uOnce the thermostat is installed, return power to heating system and switch all slave units and the master thermostat to ON.

3.4 Slave Units - GFCI Test

We recommend you test the GFCI immediately after installing the thermostat, and once a month thereafter to ensure it is operating properly.

If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and verify the installation.

nSlide the protective door upwards and make sure the switch is ON. o Press TEST.

The test is successful if the TEST warning light is ON and power is cut off.

If the test fails (first installation test):

a.Verify installation

b.Check the load wires

c.Once you've identified the problem, run the GFCI test again

If the test fails (monthly maintenance):

a.Cut power to heating system from the main power panel and call customer service

pWhen the test is successful, reset the slave unit by switching from ON to STANDBY then back to ON.

qRepeat steps 1 to 3 for all slave units.

Technical Specifications

Temperature:

-Operation: 32°F to 122°F (0°C to 50°C)

-Storage: -4°F to 122°F (-20°C to 50°C)

TH113/TH114/TH115/TH116 (A/F/AF-12VDC)

Power supply

12 V from remote unit

 

 

Maximum

up to 10 slave units per

slave units

master thermostat

 

 

Wire gauge

20 AWG

 

 

Size (H • W • D)

4.63 x 2.7 x 0.61 in.

BASE

(117.5 x 68.3 x 15 mm)

NOTE: Refer to the TH11x user guide for techni- cal specifications.

CT230-120GA/120GB/240GA/240GB

Supply

 

- PB112-120

1800 W @ 120 VAC

 

60 Hz, 15 A resistive

- PB112-240

3600 W @ 240 VAC

 

60 Hz, 15 A resistive

 

 

GFCI

GA=5 mA / GB=30 mA

 

 

Certification

c CSA us

 

 

Size (H • W • D)

4.63 x 2.7 x 1.45 in.

BASE

(117.5 x 68.3 x 37 mm)

 

 

Size (H • W • D)

4.67 x 2.74 x 0.67 in.

INTERFACE

(118.6 x 69.6 x 17 mm)

Service

If you have any questions concerning the installation of the master thermostat or slave units, contact our technical support team at:

Montreal area:

(450) 358-4600

Canada / U.S.:

1-800-831-AUBE (2823)

Fax:

(450) 358-4650

Email:

service@aubetech.com

Monday to Friday from 8:30 AM to 5:00 PM EST.

For more information on our products, visit us at www.aubetech.com

Warranty

AUBE TECHNOLOGIES INC.

ONE (1) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.

The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment.

AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:

Aube Technologies Inc.

705 Montrichard

Saint-Jean-sur-Richelieu, Quebec,

Canada J2X 5K8

400-230-000-C 5/12/05 2/2

Image 3
Contents Technical Specifications Model Selection switchTemperature Lock TH1 1 3 only Control Module InstallationIntroduction InstallationWiring Guidelines Slave Units Installation and WiringMaster Thermostat Installation and Wiring Technical SpecificationsService Warranty

TH113 AF, TH116 A, TH113 F, TH116 F, TH116 AF specifications

Aube Technologies has established itself as a leader in smart temperature control solutions, particularly with its range of programmable thermostats. Among these, the TH116 AF, TH116 F, TH113 F, TH116 A, and TH113 AF models stand out due to their unique features and innovative technologies designed for efficient heating regulation in both residential and commercial settings.

The TH116 AF model is designed primarily for electric floor heating systems. Its advanced adaptive control technology allows for real-time temperature regulation, enhancing comfort and energy savings. The user-friendly interface provides easy access to programming options, allowing users to set different temperature profiles for various times of the day. This model is especially popular for its compatibility with various floor heating technologies.

The TH116 F model is tailored for fans or convector systems, making it a versatile choice for different heating appliances. It features a built-in programming function which allows homeowners to customize heating schedules, ensuring that spaces are warm when needed without excessive energy consumption. The anti-frost setting is a notable characteristic, helping to prevent temperatures from dropping too low during winter months.

Meanwhile, the TH113 F thermostat is known for its simplicity and effectiveness, making it ideal for users who prefer straightforward functionalities. It offers a non-programmable option, yet still maintains reliable temperature control. This model includes features such as a large display for easy reading and straightforward temperature adjustment buttons.

The TH116 A model is equipped with a variety of programmable options and an intuitive interface, suitable for a range of heating systems, including electric baseboards. It supports smart heating with an eco-mode for energy-conscious users, enabling them to enjoy significant savings on energy costs.

Lastly, the TH113 AF, also known for its simplicity, includes features like a comfortable display and straightforward programming options. It stands out for its compatibility with both electric and hydronic heating systems, making it a practical solution for various heating needs.

In summary, Aube Technologies’ range of thermostats, including the TH116 AF, TH116 F, TH113 F, TH116 A, and TH113 AF models, offers a mix of advanced features and user-friendly designs. Each thermostat comes with specific functionalities tailored to different heating systems, ensuring efficient climate control and energy management for an enhanced living experience.