If your thermostat is set to conventional recovery, a

 

 

 

indication displays continuously, as shown on the

Recovery

AM

 

example display.

 

 

 

 

Mon

 

Room

 

 

Sleep

Heat

System

Heat

Fan

Auto

M14607

Conventional Recovery Modes

 

WAKE

You choose the time you want your heating or cooling system to start to reach your comfort tempera-

 

ture after the SLEEP period. Adjust this time to earlier when you know it will take longer for the

 

system to reach your comfort temperature. Adjust this time to later when you know the SLEEP

 

temperature is closer to your WAKE temperature.

 

LEAVE

You choose the time you want your heating or cooling system to start an energy-saving mode while

 

you are away (lower temperature during heating season, and higher temperature during cooling

 

season) – follows WAKE period.

 

RETURN

You choose the time you want your heating or cooling system to start to reach your comfort tempera-

 

ture after the energy-savings LEAVE period.

 

SLEEP

You choose the time you want your heating or cooling system to start an energy-savings mode while

 

you sleep-follows RETURN period.

 

 

 

Pub. No. 12-5027-01

 

63

69-1615

Image 63
Contents ASYSTAT300C shown Pub. NoPub. No 69-1615 Table of Contents Clock Setting Current Day and Time Setting System and Fan Pub. No Customizing Your Thermostat Program Options Set Up by Your American Standard DealerComfort-R Control Adaptive Intelligent Recovery Control Getting around the Keyboard Current FAN Setting Example Display Shows AutoSET Wake Times SET Sleep Times Temperatures Features Comfort-R Comfort Enhancement System Features YOU’LL Want to Know More aboutAdaptive Intelligent Recovery Control Your Thermostat Senses Temperature More Like You DoRecovery indication shown in example above Optimum Comfort Energy Savings Solution Temperature Temperature setpoint displays Neat Stuff YOU’LL be Using OftenSetting Temporary Temperatures Changing Temperature Setting Until the Next Schedule PeriodMon HeatAuto Nated time, press Run ProgramChanging Temperature Setting Indefinitely SettingPress Hold Temp once CoolAuto Setting SystemPress Increase or Decrease to adjust temperature settings Vacation Mode Press Hold Temp twiceCool Days Press Time or Time untilM14572 To return display to normal Don’t worry! You can always pressInformation Key Displaying Outdoor TemperatureDisplaying Current Settings Filter Indication Press Filter to enter the Filter mode Setting or Resetting Filter Indication TimerRun Program Setting Current Day and Time Programming Your ThermostatClock Press Set Current Day/Time Press Time or Time until the current time displays Setting System and Fan Set SystemSet Fan Day Preprogrammed Schedule Day Program and OperationDay Preprogrammed Schedule Customizing Your Own 7-Day Schedule Word About Power OutagesInstructions Your 7-Day Schedule An Extra 7-Day Schedule Wake Heat Programming the First DayPress Wake TuePress Day until the desired day displays Press Time or Time until the desired Wake time displaysMon Mon Wake Heat Schedule periodDisplays Press Increase or DecreaseLeave Return Sleep Copy from Press Wake, Leave, Return or Sleep to enter program modeCopying a Day Press Day to select the day toPress Copy Press Day until the day to be copied to is displayedMon Wed Copy Run Program Leave Heat Enter program modeClearing Schedule Period Press Leave , Return or Sleep toSat SecondsPub. No Hour Preprogrammed Schedule Hour Program and OperationCustomizing Your Own 24-Hour Schedule To program the Wake time and temperature and fan operation Programming Your 24-Hour ScheduleAn Extra 24-Hour Schedule Set Program M14602 M14603 Until the desired temperature setpoint Displays Setting Temperature and Fan Operation Constant Temperature Setpoint Programming29C for heating and 65 to 99F 18 to 37C for cooling Setting Cool Symptom Possible Cause Action Troubleshooting GuideWait Troubleshooting GuideFlame=heat Fan when the equipment has Registers Definitions Adaptive Intelligent Recovery ControlAdaptive Intelligent Recovery Modes Conventional RecoveryTure after the energy-savings Leave period Conventional Recovery ModesTemperature is closer to your Wake temperature Example displaySystem Preprogrammed SchedulePeriod SetpointDefinitions IndexLow Voltage Room Thermostats Limited WarrantyCustomer Assistance American Standard Inc

ASYSTAT302C, ASYSTAT300C specifications

The American Standard ASYSTAT300C and ASYSTAT302C are advanced cooling and dehumidification systems designed for optimal performance and energy efficiency in various indoor environments. These models cater to both residential and light commercial applications, making them versatile solutions for maintaining ideal indoor air quality and comfort.

One of the defining features of the ASYSTAT300C and ASYSTAT302C is their dual functionality. Not only do they provide cooling, but they also effectively manage humidity levels, preventing the build-up of excess moisture that can lead to mold and mildew growth. This dual action ensures a healthy living space, particularly in regions with high humidity.

Energy efficiency is another hallmark of these models. Equipped with high-efficiency compressors and advanced insulation technologies, the ASYSTAT300C and ASYSTAT302C help to reduce energy consumption while still delivering powerful cooling performance. The systems also meet or exceed ENERGY STAR certification standards, providing homeowners with potential savings on their energy bills.

The ASYSTAT300C offers a cooling capacity of up to 30,000 BTUs, making it suitable for medium to large spaces, while the ASYSTAT302C steps up the capacity to 32,000 BTUs, catering to larger environments. Both models feature variable speed motors that adapt to the cooling load, ensuring consistent comfort and minimizing energy waste.

User-friendly interfaces are another strong point of the ASYSTAT series. With intuitive controls, users can easily set their desired temperature and humidity levels. The systems offer programmable settings, allowing for tailored comfort schedules that align with the users' lifestyle, further enhancing energy savings.

The advanced technologies in the ASYSTAT300C and ASYSTAT302C also include smart diagnostics capabilities. These features provide real-time performance monitoring and alerts, allowing users and technicians to quickly identify and address any potential issues before they escalate.

Both models are designed with durability in mind, featuring robust construction materials that resist wear and tear over time. This not only extends the lifespan of the units but also reduces maintenance needs, making them a reliable choice for homeowners and business owners alike.

In summary, the American Standard ASYSTAT300C and ASYSTAT302C offer a combination of powerful cooling, efficient dehumidification, user-friendly controls, and robust build quality. These innovative features make them a smart investment for anyone looking to enhance indoor comfort while keeping energy consumption in check.