Sinclair SMF-C09AI, SMF-4E27AI, SMF-C12AI, SMF-C18AI Outdoor fan speed control, Oil return function

Page 19

2. Fan state:

Display

Corresponding mode

0Off

1Low fan

2High fan

3.Opening degree of EXV:

Opening degree equals the display data times 8; 4. Number of indoor unit

The indoor unit that can communicate with outdoor unit normally.

7.11 Outdoor fan speed control

There is one fan with two-speed, the fan speed is controlled according ambient temp. After the compressor stop, 30 seconds later the fan stop.

When cooling:

Ambient temp.rise

> 27

High speed

<27

Low speed

 

Ambient

>25

High speed

temp.decline

<25

Low speed

When heating:

 

 

Ambient temp.rise

> 14

Low speed

<14

High speed

 

Ambient

>12

Low speed

temp.decline

<12

High speed

7.12 Oil return function

If operation frequency is lower than 54Hz in 2 hours consecutively, it will be increased to 62Hz for 3 minutes. Then it recovers to the former operation frequency.

19

Image 19
Contents R410A Cassette Inverter multi Series Contents Features Indoor unit Indoor Outdoor Unit 5uF/500VAC Page Outdoor unit Indoor unit7k/9k/12k/18kIndoor unit combination Heating Capacity table SMF-4E27AI 7k+7k+7k+7kWiring Diagram Indoor unit Outdoor unit SMF-4E27AI Electric control functions Operating modeDehumidifying mode Manual switch Mode conflictTimer Function Auto restart function Indoor unit indicator display functionCooling capacity test frequency locked Check function Outdoor unit LED display functionOil return function Outdoor fan speed controlPage Page Page Page Page Page SMF-4E27AI