LG Electronics LAU121CNM, LAN121CNM, LA121HPMI Indoor unit, Outdoor unit, Rooftop Installations

Page 15

Installation

Selectthe BestLocation

Indoor unit

1.Do not have any heat or steam near the unit.

2.Select a place where there are no obstacles in front of the unit.

3.Make sure that condensation drainage can be conveniently routed away.

6.Use a stud finder to locate studs to prevent unnecessary damage to the wall.

 

More than

More than

20cm(7.9in)

 

30cm(11.8in)

 

4. Do not install near a doorway.

5. Ensure that the space around the left and right

of the unit is more than 30cm(11.8in). The unit More than 1.5m(4.9ft) should be installed as high on the wall as possi- ble, allowing a minimum of 20cm(7.9in) from

ceiling.

More than

30cm(11.8in)

Install the indoor unit on the wall where the height from the floors more than 1.5meters(7.9ft). A minimum pipe run of 7.5meters(24.6ft) is required to minimize vibration and excessive noise.

Outdoor unit

1.If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

2.Ensure that the space around the back and sides is more than 30cm(11.8in). The front of the unit should have more than 70cm(27.6in) of space.

3.Do not place animals and plants in the path of the warm air.

4.Take the air conditioner weight into account and select a place where noise and vibration are minimum.

5.Select a place so that the warm air and noise from the air conditioner do not disturb neigh- bors.

More than 60cm(23.6in)

More than

More than30cm(11.8in) 30cm(11.8in)

More than

More than

70cm(27.6in)

60cm(23.6in)

 

Rooftop Installations

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.

If the outdoor unit is installed on roof structures or walls, this may result in excessive noise and vibra- tion, and may be also classed as non serviceable installation.

Service Manual 15

Image 15
Contents Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsInstallation Do not modify or extend the power cordOperation Moisture may condense and wet or damage furnishings Keep level even when installing the product Do not block the inlet or outlet of air flow Do not direct airflow at room occupantsDisuse Do not drink the water drained from the unitReplace all the batteries in the remote Dimensions Symbols Used in this ManualIndoor Unit 12k Outdoor UnitIntroduction FeaturesInstallation Installation PartsInstallation Tools Bushing-Sleeve Installation MapThis Product Contains R-410A Refrigerant Confirm The RefrigerantRooftop Installations Indoor unitOutdoor unit Piping Length and Elevation Drill a Hole In The Wall How to Mount Installation PlatePutting nut on Flaring WorkCut the pipes and the cable Burrs removalConnecting The Piping Indoor unit installationIndoor Tighten the flare nut with a wrench Wrap the insulation material around the connecting portionIndoor unit installation Insert the connecting cable into the indoor unitPiping for passage through piping hole Incorrect case Correct caseConnection of Piping -Outdoor Connection of The Drain HoseConnection of The Cable Wiring DiagramHow to use the front panel Front panel opening Front panel closingFront panel removing Drain piping Checking The DrainageForming The Piping Leak test Air PurgingAir purging With Vacuum Pump PreparationFinishing the job EvacuationCharging Evaluation of the performance Prepare remote controlTest Running Settlement of outdoor unitFunction of Controls Cooling Mode OperationHealthy Dehumidification Mode OperationDefrost Control Heating Mode OperationJet Cool Mode Operation H/P Model Sleep Timer OperationChaos Natural Wind Mode Jet Cool Mode Operation C/O ModelProtection of the evaporator pipe from frosting Forced operationTest operation Auto restartDisplay Function Self-diagnosis FunctionHeating Model Operation Mode Remote Control OperationsTo remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover Cooling & Heating Models Troubleshooting GuideRefrigeration Cycle Diagram Cooling Only ModelsWay Valve Liquid Side Way, 3-way ValvePumping Down ProcedureBalance Refrigerant of the 3-way Valve Vacuum pump After Evacuation Gas ChargingAdditional gas charging Method of using graphMethod of using equation According to Indoor & Outdoor TemperatureTrouble analysis Cycle PartsProduct does not operate at all Electronic PartsProduct is not operate with the remote controller Compressor/Outdoor Fan are unable to drive Nector When indoor Fan does not operateWhen Vertical Louver does not operate When a comunication error occurs Indoor Unit Phenomena in case of connecting errorOutdoor Unit Electric Control Device Schematic DiagramOutdoor 12k Models 12k Wiring DiagramModels 12kC/O Models 12kH/P Components Location Outdoor12k 6306A90009A 6871A00087B6871A00088A 6871A20259DCooling Only Product SpecificationsE.R P.E Cooling & HeatingExploded View W0CZZ Outdoor Unit 12k Btu/h SeriessParts List Indoor Replacement Parts ListParts List Outdoor No. MFL31443001

LA121HPMI, LAU121CNM, LAN121CNM, LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, LA121CPMO specifications

LG Electronics has established itself as a leader in innovative home appliance technologies, particularly in the air conditioning segment. The LG LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, and LA121CPMO models exemplify the blend of efficiency, comfort, and advanced features that LG is known for.

These air conditioning units are designed with energy efficiency in mind, boasting high SEER (Seasonal Energy Efficiency Ratio) ratings that help reduce electricity consumption. This not only saves money on energy bills but also aligns with eco-friendly initiatives by minimizing environmental impact.

The air conditioners are equipped with LG's Dual Inverter technology, which enhances cooling performance while reducing noise levels. This innovative technology allows the compressor to operate at variable speeds, resulting in faster cooling and dehumidification, as well as quieter operation than traditional units.

Moreover, the models feature a modern aesthetic with sleek designs that seamlessly blend into both residential and commercial environments. The intuitive user interface, combined with remote control capabilities, makes adjusting temperature settings easier for users, giving them full control over their indoor climate.

Another significant characteristic of these models is the use of advanced filtration systems. Many units incorporate a multi-stage filtration process that captures dust, allergens, and pollutants, ensuring the air quality in the home remains high. These filters are easy to clean and replace, making maintenance straightforward and user-friendly.

The LG LAN121CNM, LAU121CNM, and others in the lineup also include Wi-Fi connectivity. This smart technology allows users to monitor and control their air conditioning units through mobile applications, providing convenience and flexibility. Users can adjust settings, schedule operations, and receive alerts about filter maintenance directly from their smartphones.

For those looking for flexibility, these models offer various installation options. They can be installed as wall-mounted, floor-mounted, or ceiling-mounted systems, catering to different space constraints and design preferences.

In conclusion, the LG LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, and LA121CPMO air conditioning models are exemplary products that demonstrate LG’s commitment to quality, efficiency, and user-centric design. With cutting-edge technology and a focus on sustainability, these units cater to the needs of modern consumers while ensuring comfort all year round.