LG Electronics LAU121CNM, LAN121CNM, LA121HPMI Do not direct airflow at room occupants

Page 7

Safety Precautions

Do not install the product where the noise or hot air from the out- door unit could damage the neighborhoods.

Use two or more people to lift and transport the air conditioner

Do not install the product where it will be exposed to sea wind (salt spray) directly.

• It may cause a problem for your

• Avoid personal injury.

• It may cause corrosion in the

neighbors.

 

product. Corrosion, particularly

 

 

on the condenser and evaporator

 

 

fins, could cause product mal-

 

 

function or inefficient operation.

Operation

Do not direct airflow at room occupants.

• This could damage your health.

Use a soft cloth to clean.

Do not use harsh detergents, solvents, etc.

There is risk of fire, electric shock or damage to the plastic parts of the product.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

There is risk of damage or loss of property.

Do not touch the metal parts of the product when removing the air filter. They are very sharp!

• There is risk of personal injury.

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Do not step on or put anything on the product. (outdoor unit)

There is risk of personal injury and failure of product.

Service Manual 7

Image 7
Contents Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsInstallation Do not modify or extend the power cordOperation Moisture may condense and wet or damage furnishings Keep level even when installing the product Do not block the inlet or outlet of air flow Do not direct airflow at room occupantsDo not drink the water drained from the unit DisuseReplace all the batteries in the remote Symbols Used in this Manual DimensionsIndoor Unit 12k Outdoor UnitIntroduction FeaturesInstallation Parts InstallationInstallation Tools Bushing-Sleeve Installation MapThis Product Contains R-410A Refrigerant Confirm The RefrigerantIndoor unit Rooftop InstallationsOutdoor unit Piping Length and Elevation Drill a Hole In The Wall How to Mount Installation PlatePutting nut on Flaring WorkCut the pipes and the cable Burrs removalIndoor unit installation Connecting The PipingIndoor Tighten the flare nut with a wrench Wrap the insulation material around the connecting portionIndoor unit installation Insert the connecting cable into the indoor unitPiping for passage through piping hole Incorrect case Correct caseConnection of Piping -Outdoor Connection of The Drain HoseConnection of The Cable Wiring DiagramFront panel closing How to use the front panel Front panel openingFront panel removing Drain piping Checking The DrainageForming The Piping Leak test Air PurgingAir purging With Vacuum Pump PreparationFinishing the job EvacuationCharging Evaluation of the performance Prepare remote controlTest Running Settlement of outdoor unitFunction of Controls Cooling Mode OperationHealthy Dehumidification Mode OperationDefrost Control Heating Mode OperationJet Cool Mode Operation H/P Model Sleep Timer OperationChaos Natural Wind Mode Jet Cool Mode Operation C/O ModelProtection of the evaporator pipe from frosting Forced operationTest operation Auto restartSelf-diagnosis Function Display FunctionHeating Model Operation Mode Remote Control OperationsTo remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover Cooling & Heating Models Troubleshooting GuideRefrigeration Cycle Diagram Cooling Only ModelsWay Valve Liquid Side Way, 3-way ValvePumping Down ProcedureBalance Refrigerant of the 3-way Valve Vacuum pump After Evacuation Gas ChargingAdditional gas charging Method of using graphMethod of using equation According to Indoor & Outdoor TemperatureTrouble analysis Cycle PartsProduct does not operate at all Electronic PartsProduct is not operate with the remote controller Compressor/Outdoor Fan are unable to drive Nector When indoor Fan does not operateWhen Vertical Louver does not operate When a comunication error occurs Indoor Unit Phenomena in case of connecting errorOutdoor Unit Electric Control Device Schematic DiagramOutdoor 12k Models 12k Wiring DiagramModels 12kC/O Models 12kH/P Components Location Outdoor12k 6306A90009A 6871A00087B6871A00088A 6871A20259DCooling Only Product SpecificationsE.R P.E Cooling & HeatingExploded View W0CZZ Outdoor Unit 12k Btu/h SeriessParts List Indoor Replacement Parts ListParts List Outdoor No. MFL31443001

LA121HPMI, LAU121CNM, LAN121CNM, LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, LA121CPMO specifications

LG Electronics has established itself as a leader in innovative home appliance technologies, particularly in the air conditioning segment. The LG LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, and LA121CPMO models exemplify the blend of efficiency, comfort, and advanced features that LG is known for.

These air conditioning units are designed with energy efficiency in mind, boasting high SEER (Seasonal Energy Efficiency Ratio) ratings that help reduce electricity consumption. This not only saves money on energy bills but also aligns with eco-friendly initiatives by minimizing environmental impact.

The air conditioners are equipped with LG's Dual Inverter technology, which enhances cooling performance while reducing noise levels. This innovative technology allows the compressor to operate at variable speeds, resulting in faster cooling and dehumidification, as well as quieter operation than traditional units.

Moreover, the models feature a modern aesthetic with sleek designs that seamlessly blend into both residential and commercial environments. The intuitive user interface, combined with remote control capabilities, makes adjusting temperature settings easier for users, giving them full control over their indoor climate.

Another significant characteristic of these models is the use of advanced filtration systems. Many units incorporate a multi-stage filtration process that captures dust, allergens, and pollutants, ensuring the air quality in the home remains high. These filters are easy to clean and replace, making maintenance straightforward and user-friendly.

The LG LAN121CNM, LAU121CNM, and others in the lineup also include Wi-Fi connectivity. This smart technology allows users to monitor and control their air conditioning units through mobile applications, providing convenience and flexibility. Users can adjust settings, schedule operations, and receive alerts about filter maintenance directly from their smartphones.

For those looking for flexibility, these models offer various installation options. They can be installed as wall-mounted, floor-mounted, or ceiling-mounted systems, catering to different space constraints and design preferences.

In conclusion, the LG LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, and LA121CPMO air conditioning models are exemplary products that demonstrate LG’s commitment to quality, efficiency, and user-centric design. With cutting-edge technology and a focus on sustainability, these units cater to the needs of modern consumers while ensuring comfort all year round.