LG Electronics 2800HT operation manual Btu, 63% Gph Lbs kg Manual Cfm total

Page 21

SPECIFICATIONS - Model 2800HT

Approx. heat capacity

Maximum log length

Flue size

Width w / standard surround

Width at fireplace opening

Width at rear of firebox

Depth into Fireplace

Depth (overall)

Height

Height w / standard surround

Back of Stove to

Center of Flue

Approx. burn time

Fuel capacity

Firebox size (cubic feet)

Maximum Burn Rate

EPA BTU Range

EPA Efficiency

Emissions Rate (grams / hour)

Approx. weight with brick

Primary Air Control

Start-up Air

Blower Assemblies

(4 fans, 125 cfm ea., .42 amps ea.)

Up to ~1800 Sq. Feet Up to ~ 550 Sq. Meters

18" (457 mm)

6" (152 mm)

42" (107 cm)

24" (610 mm)

22 ½” (572 mm)

15 ½” (394 mm)

28 ¼” (718 mm)

20" (508 mm)

32" (813 mm)

6" (152 mm)

8-10 hours

50 - 60 lbs.

(23 – 27 kg)

2.9c.f. (884 cubic mm) 74,100 BTU

11,500-46,700

BTU

63%

4.5 gph

435 lbs. (197 kg)

Manual

Manual

500 cfm total

~Square feet heating capacity and burn time are approxi- mations only. They will vary depending upon the level of insulation, climate, house design, ceiling height, ambient outside temperatures and how the stove is operated.

Dimensions shown are approximations only (+/- ¼” [6.4 mm])

PAGE 21

Image 21
Contents 775004M, Rev. J, 11/03 Installation and Operation ManualImportant Warnings Table of Contents Smoke Detectors Planning Your InstallationHearth Protection Chimney InspectionClearances Draft RequirementsProvide Adequate AIR for Combustion Factory Built Fireplaces Factory Built Fireplace InstallationNot Approved In Canada Venting Requirements for factory built fireplaceMetal Tag Masonry FireplacesInstallation Installation Steps Power Cord ChangeoverBaffle Plate MarbleWrong CorrectSurround Assembly Positive Flue Connection for Masonry Product Features and ControlsBlower System Primary AIR ControlCare and Operation AIR Draft Controls HOW to Start and Maintain a FireStart-Up Air Control RefuelingWiring Diagram Power Flow Diagram Fuel MaintenanceServicing Glass Cleaning BlowersReplacing Glass Removal of Fireplace Insert for Inspection Reinstall Baffle Plate Cleaning / Removing Baffle Plate To remove, locateTroubleshooting Overfiring Damage Dimensions shown are approximations only +/- ¼ 6.4 mm BTU63% Gph Lbs kg Manual Cfm total Description Replacement Parts List Model 2800HTReplacement Parts List Model 2800HT Component Diagrams Model 2800HT Offset Adapter SAFETY/LISTING LabelActual Appearance Masonry Fireplace Kit Zero Clearance KitSAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA