LG Electronics 2800HT operation manual Surround Assembly

Page 11

INSTALLATION

SURROUND ASSEMBLY

IMPORTANT: Do not face seal over chimney cooling air system on superior brand or any brand fireplace which is designed with the chimney cooling air system.

13.Pull the insert slightly forward to its desired position; attach the face shield using the sur- round clips and hardware as shown. The fi- berglass insulation strips should be secured along the top and sides (step 3). Assemble the gold-tone trim using the 2 inside corner brackets. Attach trim to the face shield and stove.

Push the appliance back until face shield insula- tion is compressed against the fireplace front, forming a tight seal. Test for air leaks by hold- ing a candle around edge of face shield to see if smoke is pulled into fireplace.

*Note: Preferred method of attaching connector to flue outlet is to install two L-Brackets (1” [25.4 mm] angle bracket, 3/4” [19 mm] wide) on oppo- site sides of the flue outlet: Use self-tapping screws to secure in place. Cut a ½” (13 mm) (height) and ¾” (19 mm) (width) notch in the front of connector (pipe, liner or adapter that will attach to flue outlet). Install connector into flue outlet and secure to angle brackets using machine screws. Seal around connection with furnace cement.

POSITIVE FLUE CONNECTION FOR MASONRY FIREPLACE Note: Be sure the damper is locked in the open position.

A Professional should inspect chimney prior to installation to deter- mine if any repairs are necessary or if a chimney reline is necessary. The fireplace damper must be secured in the open position. If this is not possible, it will be necessary to remove the damper. Installation into a masonry fireplace requires as a minimum of a flue extension past the header. This can be accomplished by one of the following methods:

Install 6" (152 mm) smoke pipe if the chimney is located directly above the insert flue outlet.

(or) Install 6" (152 mm) flex pipe to achieve the same result.

Use an offset adapter (see page 26) to handle offsets. This part is available through your dealer.

PAGE 11

Image 11
Contents 775004M, Rev. J, 11/03 Installation and Operation ManualImportant Warnings Table of Contents Chimney Inspection Planning Your InstallationSmoke Detectors Hearth ProtectionProvide Adequate AIR for Combustion ClearancesDraft Requirements Venting Requirements for factory built fireplace Factory Built Fireplace InstallationFactory Built Fireplaces Not Approved In CanadaMetal Tag Masonry Fireplaces Installation Marble Power Cord ChangeoverInstallation Steps Baffle PlateWrong CorrectSurround Assembly Primary AIR Control Product Features and ControlsPositive Flue Connection for Masonry Blower SystemCare and Operation Refueling HOW to Start and Maintain a FireAIR Draft Controls Start-Up Air ControlWiring Diagram Power Flow Diagram Fuel MaintenanceRemoval of Fireplace Insert for Inspection Cleaning BlowersServicing Glass Replacing GlassReinstall Baffle Plate Cleaning / Removing Baffle Plate To remove, locateTroubleshooting Overfiring Damage 63% Gph Lbs kg Manual Cfm total Dimensions shown are approximations only +/- ¼ 6.4 mmBTU Description Replacement Parts List Model 2800HTReplacement Parts List Model 2800HT Component Diagrams Model 2800HT Zero Clearance Kit SAFETY/LISTING LabelOffset Adapter Actual Appearance Masonry Fireplace KitSAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA