6.Pull cable to full extension.

7.Screw ferrule on to cable (approximately 4-5 turns maximum).

8.Slide o-ring onto cable shaft.

9.Screw red T-handle onto cable shaft (Do not obstruct cross hole in T- handle).

10.Push red T-handle into ferrule to seat o-ring.

11.Align holes in ferrule and T-handle.

12.Temporarily install pull pin.

13.Align T-handle so the word “FIRE” is vertical.

14.Tighten the nut behind the panel.

15.Recheck cable installation.

16.CABLE MUST NOT BE CONNECTED TO CYLINDER AT THIS TIME.

17.Remove pull pin.

18.Pass the red tamper proof seal through the ring of the pull pin and around the ferrule.

19.Insert the free end of the seal into the projecting portion of the tab end (marked “enter”).

20.Pull seal snug to secure the pull pin from accidental release.

Dual Release Adapter:

If the vessel has more than one helm, a Dual Release Adapter , DRA- 1001-01 is required (see Additional Equipment)

Follow the instructions enclosed with the dual release adapter

Connecting cable to cylinder – See Illustration Below

1.Mount cylinder as described (see Marine Installation Instructions).

2.Insert cable end into the hole in the top of the extinguisher manifold.

12

Image 12
Contents 18004 Page Approved for use within the European Union Page Page Page Page Accommodating Diesel Engines Page Cable Installation Do not connect cable to cylinder at this time Cable Must not be Connected to Cylinder AT this Time Operation of Fireboy Fire Extinguisher Maintaining Fireboy Fire Extinguisher Page Description Page Year Limited Warranty

HFC-227ea, MA2 FE-241, CG2 specifications

Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 is an advanced fire suppression agent that stands out in its effectiveness and versatility. This halocarbon compound, also known as heptafluoropropane, has become a preferred choice for fire protection systems worldwide due to its unique chemistry and performance characteristics.

One of the main features of HFC-227ea is its ability to suppress flames without leaving behind damaging residues. This property makes it particularly suitable for use in sensitive environments like data centers, server rooms, and heritage sites where traditional water-based extinguishing systems could cause significant collateral damage. HFC-227ea operates effectively through a combination of cooling and chemical interruption of the combustion process.

The technology behind HFC-227ea is primarily rooted in its physical and chemical properties. It is a clean agent, meaning it does not conduct electricity, and it has a low boiling point, allowing it to vaporize quickly and fill a room efficiently. Its rapid vaporization facilitates swift deployment during a fire event, ensuring prompt control and suppression of flames. Moreover, this agent is recognized for its minimal impact on the environment, with a low ozone depletion potential and a global warming potential that is considerably lower than that of many other halon alternatives.

In terms of characteristics, the HFC-227ea system is designed to operate alongside various detection and control technologies. Fireboy Xintex utilizes advanced fire detection systems that can identify smoke and heat sources rapidly, enabling quick activation of the suppression system. This integration enhances overall fire safety and responsiveness.

Additionally, the system's modular design allows for easy scalability and customization according to the specific needs of different environments. Whether in maritime applications, industrial plants, or commercial infrastructures, the flexibility and adaptability of HFC-227ea make it a prominent choice in the fire suppression landscape.

In conclusion, Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 represents a cutting-edge solution in the field of fire protection. With its clean, efficient, and environmentally conscious characteristics, it not only meets the demands of modern fire safety but does so in a way that protects valuable assets and minimizes risk.