Fireboy- Xintex, LTD MA2 FE-241, HFC-227ea, CG2 owner manual

Page 2

This owner’s manual and installation instructions pamphlet is provided in English. Additional copies in English are available at no charge by contacting the manufacturer, distributor or dealer. Copies in the language of destination are available upon request for an additional fee. Fireboy-Xintex reserves the right to change features without notice.

WARNING:

Do not handle by actuator

Do not drop

Keep away from children

Keep away from extreme heat

Do not discharge any Fireboy automatic or manual/automatic system unless securely fastened in accordance with the owner’s manual

Never attempt to manually discharge a CG2 Fireboy system

Never attempt to disassemble any component of this system

Always wear eye, face and body protection when installing, removing or working in the immediate vicinity of this system

Principle health hazards

Death without warning if high concentrations are inhaled

Reduced oxygen available for breathing

Frostbite from liquid contact

Increased susceptibility to the toxicity of excess exposure for individuals with pre-existing diseases of the central nervous system, cardiovascular system, lungs or kidneys

Toxic by-products are produced when this agent extinguishes fire

Medical instructions

If high concentrations are inhaled, immediately move the exposed to fresh air and keep calm

If not breathing, give artificial respiration. Seek medical assistance

If breathing is difficult give oxygen. Seek medical assistance

In case of skin contact immediately flush skin with water for 15 minutes

Treat for frostbite if necessary by gently warming affected area. Seek medical assistance if irritation is present

In case of eye contact, immediately flush eyes with plenty of water for at least 15 minutes. Seek medical assistance

Wash contaminated clothing before reuse

Fireboy FE-241 Systems contain Chlorotetrafluoroethane. Chlorotetrafluoroethane has been accepted by the EPA as a suitable alternate to Halon. Fireboy FM Component Approved HFC-227ea Systems contain Heptafluoropropane. Heptafluoropropane has been accepted by the EPA and EU as a suitable alternate to Halon. None of the components in these materials are listed by IARC, NPT, OSHA or ACGIH as a carcinogen.

2

Image 2
Contents 18004 Page Approved for use within the European Union Page Page Page Page Accommodating Diesel Engines Page Cable Installation Do not connect cable to cylinder at this time Cable Must not be Connected to Cylinder AT this Time Operation of Fireboy Fire Extinguisher Maintaining Fireboy Fire Extinguisher Page Description Page Year Limited Warranty

HFC-227ea, MA2 FE-241, CG2 specifications

Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 is an advanced fire suppression agent that stands out in its effectiveness and versatility. This halocarbon compound, also known as heptafluoropropane, has become a preferred choice for fire protection systems worldwide due to its unique chemistry and performance characteristics.

One of the main features of HFC-227ea is its ability to suppress flames without leaving behind damaging residues. This property makes it particularly suitable for use in sensitive environments like data centers, server rooms, and heritage sites where traditional water-based extinguishing systems could cause significant collateral damage. HFC-227ea operates effectively through a combination of cooling and chemical interruption of the combustion process.

The technology behind HFC-227ea is primarily rooted in its physical and chemical properties. It is a clean agent, meaning it does not conduct electricity, and it has a low boiling point, allowing it to vaporize quickly and fill a room efficiently. Its rapid vaporization facilitates swift deployment during a fire event, ensuring prompt control and suppression of flames. Moreover, this agent is recognized for its minimal impact on the environment, with a low ozone depletion potential and a global warming potential that is considerably lower than that of many other halon alternatives.

In terms of characteristics, the HFC-227ea system is designed to operate alongside various detection and control technologies. Fireboy Xintex utilizes advanced fire detection systems that can identify smoke and heat sources rapidly, enabling quick activation of the suppression system. This integration enhances overall fire safety and responsiveness.

Additionally, the system's modular design allows for easy scalability and customization according to the specific needs of different environments. Whether in maritime applications, industrial plants, or commercial infrastructures, the flexibility and adaptability of HFC-227ea make it a prominent choice in the fire suppression landscape.

In conclusion, Fireboy Xintex, LTD HFC-227ea, CG2, MA2 FE-241 represents a cutting-edge solution in the field of fire protection. With its clean, efficient, and environmentally conscious characteristics, it not only meets the demands of modern fire safety but does so in a way that protects valuable assets and minimizes risk.