SEDIMENT TRAPS

A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation shown in Figures 12 and 13.

Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the “Gas Piping” section. Refer to the current edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54.

FIGURE 14.

FILLING THE WATER HEATER

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

To fill the water heater with water:

1.Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

2.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

3.To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

4.Check all water piping and connections for leaks. Repair as needed.

BLOWER ASSEMBLY INSTALLATION

SEQUENCE OF INSTALLATION

1. This power vented water heater comes with the blower assembly installed.

2After the unit is set in place, make sure the blower assembly is still mounted securely and the air intake screen of the blower assembly is installed in the dilution air opening. Also make sure the drain

port of the rubber boot vent adapter is capped off. Lastly, make sure there is no damage to the blower.

3.Make sure there is no packing material in the discharge of the blower or the intake of the dilution air restrictor, see Figure 15.

4.Make sure that the plastic tubing is still attached from the air pressure switch to the port on the blower housing. Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower housing.

5.Make sure the ON/OFF switch is in the OFF position and that the outer harness is connected from the blower control box to the connector on the bottom side of the gas control valve.

6.If the outer harness is not factory installed, make sure the ON/OFF switch is in the OFF position and then connect the outer harness from the blower control box to the connector on the bottom side of the gas control valve.

7.This water heater is a polarity sensitive appliance and will not operate if the power supply polarity is reversed. The power supply or outlet providing power to this water heater must be wired properly (correct polarity).

8.Do not plug in power cord until vent system is completely installed. This powered vent heater operates on 110-120 Vac, therefore a grounded outlet must be within reach of the six (6) foot (1.8 m) flexible power cord supplied with the unit (see Figure 1). The power cord supplied may be used only where local codes permit. If local codes do not permit the use of a flexible power supply cord:

a.) Make sure the unit is unplugged from wall outlet. Remove screws and open panel on front of control box.

b.) Cut the flexible power cord, leaving enough to be able to make connections, the remove the strain relief fitting from box.

c.) Install suitable conduit fitting in side of enclosure and then follow (d.) and (e.) below.

d.) Splice field wiring into existing wiring using code authorized method (wire nuts, etc.).

e.) Be certain that neutral and live connections are not reversed when

making these connections.

f.) Close panel on the side of control box, make sure that access panel is secured shut.

14

Image 14
Contents AN Odorant is Added to the GAS Used By this Water Heater PrintedSafe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionKeep Clear of ALL Obstructions Natural HOT Surface Igniter & Main Burner Typical InstallationDrain Pan Propane HOT Surface Igniter & Main BurnerMixing Valve Usage Hotter Water can ScaldLocating the NEW Water Heater Facts to Consider about the LocationInsulation Blankets ALL AIR from Inside Buildings See ALL AIR from Outdoors See Figures 7, 8Closed Water Systems Installing the NEW Water HeaterWater Piping Thermal ExpansionTEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if suppliedGAS Piping with Flexible Connector GAS PipingSediment Traps Blower Assembly InstallationSequence of Installation Filling the Water HeaterVent Connections to Blower Assembly Venting and InstallationCondensate Maximum and Minimum Vent LengthsMasonry Side Walls Vent Terminal InstallationVenting Wooden Side WallsVertical Vent Termination Restrictions Vertical Vent Through RoofVent Pipe Preparation Recommended BRUSH* Size for Primer Cement ApplicationsStep F Step BStep E Step GPage Temperature Regulation GAS Control Valve Front ViewFor Your Information Start UP ConditionsVenting System Inspection Periodic MaintenanceBurner Cleaning Burner Operation and InspectionAnode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationDrain Valve Washer Replacement DrainingService Leakage CheckpointsNot Shown Optional Repair Parts ListBurner Assembly Drain PAN Outer Door Alternate Troubleshooting Guidelines Trouble ShootingPage Troubleshooting Guidelines Important Information Tennessee Waltz Parkway Ashland City, TN

GS6 50 YBVIT, GS6 40 YRVIT, GS6 50 YBVIT 2, GS6 40 YBVIT 2, 315466-000 specifications

State Industries manufactures a variety of high-efficiency water heaters, including the GS6 models, which are designed to meet diverse residential and commercial needs. Among these, the GS6 50 YRVIT, GS6 40 YBDS, and GS6 40 YBVIT 2 stand out for their performance, advanced technologies, and distinctive features.

The GS6 50 YRVIT is a powerful 50-gallon gas water heater that boasts a 40,000 BTU input. This model is designed with a high-efficiency rating, enabling it to deliver a strong hot water supply while minimizing energy costs. Its glass-lined tank provides superior protection against rust and corrosion, ensuring durability and extending the lifespan of the unit. This model also features an innovative flue design that maximizes combustion efficiency, making it an environmentally friendly choice that adheres to stringent energy regulations.

The GS6 40 YBDS, on the other hand, is a more compact 40-gallon gas water heater, also with a 40,000 BTU input. This unit is particularly popular for smaller households or commercial spaces where space is limited. It also incorporates advanced technology to optimize performance while remaining user-friendly. The GS6 40 YBDS is equipped with a direct vent system, allowing for flexible installation options, ensuring that high-efficiency heating is available even in confined areas.

Lastly, the GS6 40 YBVIT 2 model takes energy efficiency a step further with its cutting-edge insulation system and advanced temperature control features. This 40-gallon water heater is specifically engineered to minimize heat loss, which translates into reduced energy expenses for the user. The stainless steel burner and exceptional venting design contribute to efficient hot water production, making the GS6 40 YBVIT 2 a reliable choice for families seeking consistent performance.

Across all GS6 models, State Industries emphasizes safety and reliability. Each unit includes several built-in safety features, such as a temperature and pressure relief valve and a flame arrestor to prevent flammable vapors from entering the burner. Moreover, the easy-to-use digital display allows users to monitor settings effortlessly.

In summary, the State Industries GS6 series, including the GS6 50 YRVIT, GS6 40 YBDS, and GS6 40 YBVIT 2, combines efficiency, cost-effectiveness, and advanced technologies, catering to the hot water needs of any home or business. With their robust construction and innovative features, these water heaters provide dependable service and peace of mind to users.