State Industries Power Vent/Power Direct Vent Gas Models Power Vent Wiring Schematic Figure

Page 29

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

THIS WATER HEATER

IS POLARITY SENSITVE.

BEFORE APPLYING

ELECTRICITY TO THIS

HEATER BE CERTAIN

THAT SUPPLY NEUTRAL

WIRE TO GROUND

CHECK INDICATES ZERO

VOLTAGE.

POWER VENT WIRING SCHEMATIC - FIGURE 24.

29

Image 29
Contents 197834-000 Whenever maintenance adjustment or service is requiredImportant Definitions Safe INSTALLATION, USE and ServiceGeneral Safety General Safety Introduction Table of ContentsGET to Know Your Water Heater GAS Models Replacement Parts and Deliming ProductsRough-In-Dimensions Installation ConsiderationsRecovery capacity based on 96% thermal efficiency All models Maximum Supply Pressure 14 inches W.C .48kPaDirectly BELOW. Keep Clear of ALL Obstructions Water Piping Mixing Valve Usage Facts to Consider About the Location Combustion AIR and Ventilation Insulation BlanketsAppliances in Unconfined Spaces Appliances in Confined SpacesALL AIR from Outdoors See Figures 7, 8 ALL AIR from Inside Buildings SeeChemical Vapor Corrosion Installing the NEW Water HeaterWater Piping Closed Water SystemsValve and Pipe Insulation if supplied Temperature-Pressure Relief ValveGas Piping High Altitude InstallationsVent Pipe Termination Sediment Traps VentingFilling the Water Heater Vent Hoods MAY be Extremely HOT During Operation Power VentCanadian Power Vent Canadian Direct Vent Direct VentCondensate InstallationsPlanning the Vent System Vent Terminal INSTALLATION, Sidewall Installation of Vent SystemSequence of INSTALLATIONS, a Direct Vent Terminal Installation ImportantVent Terminals Supplied with Heater Must be Used Installation SequenceVertical Vent Terminal Installation Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallConcentric Vent Installation KIT ComponentsInstallation Procedure 1 Roof TERMINATION, see Figure C Safety ConsiderationsFigure F Procedure 2 Side Wall TERMINATION, see Figure FFigure g MULTI-CONCENTRIC Vent TerminationsVent Pipe Preparation Step E Step BStep F Step GBlocked Exhaust Switch Blower Prover SwitchBlocked Intake Switch ON/OFF SwitchPower Vent Wiring Schematic Figure Do not try to light the burner by hand ON/OFF SwitchWhat to do if YOU Smell GAS Do not TRY to Light the Burner by HandHI Limit Switch E.C.O Temperature RegulationOverview Using the Electronic ControllerDisplay Action Operating StatesAction Access to the Current Fault or Warning Fault and Warning ConditionsChanging the Display Units DisplayViewing Information About the Heater Viewing the Fault HistoryOperational Conditions For Your InformationStart UP Conditions Burner Cleaning Periodic MaintenanceVenting System Inspection Burner Operation and InspectionDraining Temperature-Pressure Relief Valve OperationAnode ROD Inspection Leakage Checkpoints ServiceProblems Troubleshooting GuidelinesPage Page Limited Warranty

Power Vent/Power Direct Vent Gas Models specifications

State Industries offers a range of power vent and power direct vent gas models that cater to various residential and commercial heating needs. These models are designed for efficiency, safety, and convenience, making them a popular choice among consumers seeking reliable water heating solutions.

One of the standout features of State Industries' power vent models is their ability to vent directly through walls or roofs, enabling installation in locations where traditional venting methods may pose challenges. This flexibility makes them ideal for homes without suitable chimney access. The power vent system employs a fan to push exhaust gases out, ensuring efficient operation even in cases where vertical venting is not feasible.

The power direct vent models take this a step further by utilizing sealed combustion technology. This means they draw air for combustion from outside the home, which significantly reduces the risk of backdrafts and improves indoor air quality. The dual-venting system of these models also enhances their efficiency, as it allows for better control of air flow and exhaust.

State Industries incorporates advanced technologies in their gas models, including electronic ignition systems that eliminate the need for a standing pilot light. This feature not only enhances energy efficiency but also adds convenience for users. Moreover, these models come equipped with LED indicators that provide real-time status updates, enabling users to monitor their units easily.

Durability and reliability are hallmarks of State Industries products. The tanks are constructed with high-quality materials and feature protective coatings that inhibit corrosion, ensuring a long lifespan. In addition to this, many models are backed by extended warranties, providing peace of mind for consumers.

Energy efficiency is a critical characteristic of these gas models, with many units meeting or exceeding energy efficiency standards set by the Environmental Protection Agency (EPA). This results in lower utility bills and a reduced environmental impact. With adjustable temperature settings, users can optimize their water heating experience while conserving energy.

In conclusion, State Industries' power vent and power direct vent gas models stand out for their flexibility in installation, advanced technologies, and energy-efficient operation. Whether for residential or commercial use, these models offer high performance and reliability, ensuring that users enjoy a consistent and efficient hot water supply.