Multiquip px400, cx400 manual Pump SaFetY, „ never disconnect any emergency or

Page 6

Safety Information

pump SaFetY

danger

„ never operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

Warning

„ Accidental starting can cause severe injury or death. alWaYS place the ON/OFF switch in the OFF position.

„do not place hands or fingers inside

pump when pump is running.

„never disconnect any emergency or

safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

„Risk of Electric Shock - This pump has not been investigated for use in swimming pool or marine areas.

caution

„do not restrict the fl ow of the discharge hose as it may cause the pump to overheat.

„Be careful of discharge hose whipping under pressure.

„alWaYS check pump oil level only when pump is cool. Expansion due to heat may cause hot oil to spray from the oil plug when the oil plug is removed. The possibility of severe scalding may exist.

NOTICE

„alWaYS place the pump in an upright position on a platform before using.The platform will prevent the pump from burrowing itself on soft sand or mud.

„never operate pump on its side.

„do not allow the pump to freeze in water.

„never leave an open pump chamber unattended.

„alWaYS keep the machine in proper running condition.

„do not attempt to thaw out a frozen pump by using

a torch or other source of fl ame. Application of heat in this manner may heat the oil in the seal cavity above the critical point, causing pump damage.

„do not pump water with a temperature greater than 104°F.

„do not pump liquids containing acid or alkali.

„alWaYS check strainer before pumping. Make sure strainer is not clogged. Remove any large objects, dirt or debris from the strainer to prevent clogging.

„alWaYS use a large basket strainer when pumping water that contains large debris.

„alWaYS fl ush pump (clean) after use when pumping water concentrated with heavy debris. It is very important to always fl ush the pump before turning it off to prevent clogging.

„Fix damage to machine and replace any broken parts immediately.

„alWaYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

„never lubricate components or attempt service on a running machine.

„never run pump dry.

„alWaYS allow the machine a proper amount of time to cool before servicing.

„Keep machine in proper running condition. electrical SaFetY

danger

„ The electrical voltage required to operate pump can cause severe injury or even death through physical contact with live circuits. alWaYS disconnect electrical power from pump before performing maintenance on pump.

Warning

„To reduce the risk of electric shock, connect only to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).

page 6 — cx400/px400 Sub. pump • operation and parts manual — rev. #1 (12/03/10)

Image 6
Contents Model cx400/px400 Table of Contents CX400/PX400 Submersible PumpChoose from three easy options SaFetY SYmbolS Safety InformationSaFetY meSSageS SymbolGeneral SaFetY Pump SaFetY „ do not attempt to thaw out a frozen pump by using„ never disconnect any emergency or LiFting SaFetY Power Cord/Cable SafetyControl box Safety Grounding SafetyDimensions PX400Model Voltage Type SpecificationModel CX400/PX400 UL/CSAPerformance curve Pump Performance CurveGeneral information Components Allows the pump to run dry for a limited period of timeDirect power operation Direct Power OperationDesign Features Float switchesMechanical Float Switch How It WorksFloat Switches Mounting The Float SwitchesFloat switches control box CB3 Control BoxHose Connections Pump Power Connections No Control BoxOperation Attaching Lifting RopePower Cord Requirements Control Box InstallationSingle-Phase Power Installation Input Control Box MountingConnecting AC Power to the Pump Motor Connecting Dual float Switch SW-1WOP To Control BoxConnecting AC Power to the CB3 Control Box ContractorAutomatic Operation Turning On The PumpManual Operation Shut-DownLubrication MaintenanceCleanup Lay pump flat on its side PX400 only as shown in FigureImpeller/Mechanical Seal Replacement PX400 Impeller/Mechanical Seal Replacement CX400Remove the bolts securing the casing cover to the casing Electrical Insulation Testing Why perform electrical insulation testing?Symptom SolutionCb3 Control BoX wiring diagram Wiring DiagramExplanation of Code in Remarks Column Suggested Spare Parts To 3 UnitsQty Description CX400 pump assy Part Name QTY PX400 pump assy Part Name QTY Remarks Terms and Conditions of Sale Parts FreigHt policYPage HERE’S HOW to GET Help

px400, cx400 specifications

The Multiquip CX400 and PX400 are cutting-edge equipment designed to make tasks in construction and landscaping more efficient and effective. These models are well-regarded for their reliability, durability, and advanced features, making them suitable for a wide range of applications.

The CX400 is known for its robust construction and powerful performance. It features a heavy-duty frame, which provides excellent stability during operation. The model is equipped with a reliable engine that ensures high torque and performance, allowing it to tackle various tasks with ease. Additionally, the CX400 boasts advanced hydraulic systems that enhance its lifting capacity and operational efficiency, making it ideal for heavy lifting and material handling in various environments.

On the other hand, the PX400 is designed for versatility and efficiency. This model is particularly well-suited for urban applications and tighter spaces due to its compact design. Despite its smaller size, the PX400 doesn't compromise on power. It offers an impressive lifting capacity and is equipped with a smooth-operating hydraulic system that allows for precise control during operation.

Both models come with user-friendly controls that simplify operation and increase productivity. The ergonomic design of the operator’s platform ensures comfort during extended use. Additionally, these machines feature enhanced safety features, including a robust guarding system and emergency stop functions, ensuring the safety of operators and personnel on job sites.

Another notable characteristic of the CX400 and PX400 is their fuel efficiency. Designed with modern engines that minimize fuel consumption while maximizing output, these models can significantly reduce operational costs over time. They are also engineered for easy maintenance, featuring accessible components that make routine checks and servicing straightforward.

Moreover, the Multiquip CX400 and PX400 are compatible with various attachments, allowing users to customize their machines for specific tasks. This adaptability makes them an invaluable asset to contractors and equipment rental companies alike.

In conclusion, the Multiquip CX400 and PX400 stand out in the construction and landscaping industry due to their powerful performance, advanced technologies, user-friendly features, and versatility. They are engineered to meet the demands of modern job sites while ensuring safety, efficiency, and reliability. Whether for heavy lifting or operating in confined spaces, these machines are equipped to handle a range of tasks effectively.