Safety Information

NOTICE

„alWaYS make certain that the voltage supplied to the pump is correct. Always read the pump’s nameplate to determine what the power requirements are.

Power Cord/Cable Safety

danger

„never let power cords or cables lay in water.

„never stand in water while AC power cord is connected to a live power source.

„never use damaged or worn cables or cords. Inspect for cuts in the insulation.

„ never grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

„Make sure power cables are securely connected to the motor's output receptacles. Incorrect connections may cause electrical shock and damage to the motor.

control box Safety

danger

„alWaYS have a qualifi ed electrician perform the control box installation. The possibility exists of electrical shock or electrocution.

NOTICE

„alWaYS mount control box in a vertical position protected from harsh environmental elements.

liFting SaFetY

caution

„When raising or lowering of the pump is required, always attach an adequate rope or lifting device to the correct lifting point (handle) on the pump.

NOTICE

„do not lift machine to unnecessary heights.

„never lift the equipment while the electric motor is running.

Warning

„never attempt to use the power cord as a lifting or lowering device for the pump.

NOTICE

„alWaYS make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.

Grounding Safety

danger

„alWaYS make sure pump is grounded.

„never use gas piping as an electrical ground.

„alWaYS make sure that electrical circuits are properly grounded to a suitable earth ground (ground rod) per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death by electrocution can result from operating an ungrounded motor.

tranSporting SaFetY

NOTICE

„alWaYS shut down pump before transporting.

„alWaYS tie down equipment during transport by securing the equipment with rope.

environmental SaFetY/decommiSSioningCE

„do not pour waste or oil directly onto the ground, down a drain or into any water source.

„Contact your country's Department of Public

Works or recycling agency in your area and arrange for proper disposal of any electrical components, waste or oil associated with this equipment.

„When the life cycle of this equipment is over it is recommended that the pump casing and all other metal parts be sent to a recycling center

Metal recycling involves the collection of metal from discarded products and its transformation into raw materials to use in manufacturing a new product.

Recyclers and manufacturers alike promote the process of recycling metal. Using a metal recycling center promotes energy cost savings.

cx400/px400 Sub. pump • operation and parts manual — rev. #1 (12/03/10) — page 7

Image 7
Contents Model cx400/px400 CX400/PX400 Submersible Pump Table of ContentsChoose from three easy options Symbol Safety InformationSaFetY meSSageS SaFetY SYmbolSGeneral SaFetY „ do not attempt to thaw out a frozen pump by using Pump SaFetY„ never disconnect any emergency or Grounding Safety Power Cord/Cable SafetyControl box Safety LiFting SaFetYPX400 DimensionsUL/CSA SpecificationModel CX400/PX400 Model Voltage TypePump Performance Curve Performance curveGeneral information Allows the pump to run dry for a limited period of time ComponentsDirect Power Operation Direct power operationHow It Works Float switchesMechanical Float Switch Design FeaturesMounting The Float Switches Float SwitchesCB3 Control Box Float switches control boxAttaching Lifting Rope Pump Power Connections No Control BoxOperation Hose ConnectionsControl Box Mounting Control Box InstallationSingle-Phase Power Installation Input Power Cord RequirementsContractor Connecting Dual float Switch SW-1WOP To Control BoxConnecting AC Power to the CB3 Control Box Connecting AC Power to the Pump MotorShut-Down Turning On The PumpManual Operation Automatic OperationLay pump flat on its side PX400 only as shown in Figure MaintenanceCleanup LubricationImpeller/Mechanical Seal Replacement CX400 Impeller/Mechanical Seal Replacement PX400Remove the bolts securing the casing cover to the casing Why perform electrical insulation testing? Electrical Insulation TestingSolution SymptomWiring Diagram Cb3 Control BoX wiring diagramExplanation of Code in Remarks Column To 3 Units Suggested Spare PartsQty Description CX400 pump assy Part Name QTY PX400 pump assy Part Name QTY Remarks FreigHt policY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

px400, cx400 specifications

The Multiquip CX400 and PX400 are cutting-edge equipment designed to make tasks in construction and landscaping more efficient and effective. These models are well-regarded for their reliability, durability, and advanced features, making them suitable for a wide range of applications.

The CX400 is known for its robust construction and powerful performance. It features a heavy-duty frame, which provides excellent stability during operation. The model is equipped with a reliable engine that ensures high torque and performance, allowing it to tackle various tasks with ease. Additionally, the CX400 boasts advanced hydraulic systems that enhance its lifting capacity and operational efficiency, making it ideal for heavy lifting and material handling in various environments.

On the other hand, the PX400 is designed for versatility and efficiency. This model is particularly well-suited for urban applications and tighter spaces due to its compact design. Despite its smaller size, the PX400 doesn't compromise on power. It offers an impressive lifting capacity and is equipped with a smooth-operating hydraulic system that allows for precise control during operation.

Both models come with user-friendly controls that simplify operation and increase productivity. The ergonomic design of the operator’s platform ensures comfort during extended use. Additionally, these machines feature enhanced safety features, including a robust guarding system and emergency stop functions, ensuring the safety of operators and personnel on job sites.

Another notable characteristic of the CX400 and PX400 is their fuel efficiency. Designed with modern engines that minimize fuel consumption while maximizing output, these models can significantly reduce operational costs over time. They are also engineered for easy maintenance, featuring accessible components that make routine checks and servicing straightforward.

Moreover, the Multiquip CX400 and PX400 are compatible with various attachments, allowing users to customize their machines for specific tasks. This adaptability makes them an invaluable asset to contractors and equipment rental companies alike.

In conclusion, the Multiquip CX400 and PX400 stand out in the construction and landscaping industry due to their powerful performance, advanced technologies, user-friendly features, and versatility. They are engineered to meet the demands of modern job sites while ensuring safety, efficiency, and reliability. Whether for heavy lifting or operating in confined spaces, these machines are equipped to handle a range of tasks effectively.