Instruction Manual
1.Safety Instructions
•To ensure sufficient convection cooling, always maintain a safety distance of >20mm from all ventilated surfaces while the device is in operation.
•The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
•Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
•Do not touch the terminals while power is being supplied. Risk of electric shock.
•Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause:
-Electric shock; Safety Hazard; Fire; Product failure
•Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection.
2.Device Descriptions Refer to Fig. 1:
1 Input & Output terminal block connector
2 DC voltage adjustment potentiometer
3 DC OK control LED (green)
Ventilated surface | Side surface |
|
Top
3
2
Base surface | 1 |
Fig. 1 | Device Descriptions |
PMC-24V050W1AA
3.Installation of the Device Refer to Fig. 2:
AMounting holes for power supply assembly onto the mounting surface. Power supply shall be mounted on minimum 2 mounting holes using M3 screw, minimum 5mm length.
BThis surface belongs to customer’s end system or panel where the power supply is mounted.
CConnector
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
Fig. 2 Mounting
•Use flexible cable (stranded or solid), AWG no.
Lug | Fig. 3 Wire Type | Stripped wire |
4.Installation of Mounting Accessories
•Only use M3 screw < 6mm through the base mounting holes. This is to keep a safety distance between the screw and internal components.
•Refer to Fig. 4:
Recommended mounting tightening torque: 4 ~ 8Kgf.cm
www.delta.com.tw/industrialautomation
Fig. 4 Mounting Screw