GE ZDP36N4RHSS4 dimensions Electrical Requirements, Gas Supply, Optional Backsplash Accessories

Page 2

ZDP36N4RHSS

ZDP36L4RHSS

(Natural Gas) (Liquid Propane)

GE Monogram 36" Dual Fuel Professional Range with 4 Burners and Grill

Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The receptacle must be a NEMA 14-50R device to accept the four-prong plug on the range.

Locate gas and electric as shown

4"

 

4"

4"

 

 

12"

 

 

12"

 

 

4"

 

 

 

 

 

1-1/2"

 

 

 

 

 

Gas

 

 

Electric

 

 

 

 

 

Supply

36"

Supply

 

 

 

 

 

Gas Supply

Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator.

The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator.

Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non-combustible backsplash can be used.

Backsplashes: Order one with a 36"-wide range ZX12B36HSS–12" backsplash ZX22B36HSS–22" backsplash with warming shelf

Backsplash with Warming Shelf

All Monogram Professional Wall-Mounted Hoods feature infrared warming lights. The 22"-high backsplash with warming shelf is a perfect complement when installed with the tapered or straight-sided hoods.

If you choose to install this range with a Restaurant-Style Professional Hood (ZV36RSFSS), no additional accessories are required. These hoods are shipped with a stainless steel backsplash and warming shelf.

Side View with Required Backsplashes

12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash

36" Min.

to Combustibles

Backguard

0" Clearance

 

 

Listed by

 

 

Underwriters

 

R

Laboratories

 

 

 

For answers to your Monogram,® GE Profileor

 

GE® appliance questions, visit our website at

 

GEAppliances.com or call GE Answer Center®

Specification Revised 10/05

service, 800.626.2000.