Dayton 3VG80 instruction manual Accessories, Wiring Diagram, 100,000 BUT/HR Model

Page 10

Dayton Operating Instructions and Parts Manual

3VG80

Dayton® Propane

Construction Heater

Accessories

Description

Part No.

 

 

Regulator

LPA2150

Hose and Regulator Assembly

LPA3100

10' Hose Assembly

LPA1000

Fuel Gas Connector

LPA4020

Wiring Diagram

100,000 BUT/HR MODEL

 

 

 

 

 

Motor

 

 

Black

White

 

Green

 

 

 

 

Power

Green

 

 

Green

 

 

 

 

Cord

 

White

 

Black

 

 

 

 

 

Terminal Board

 

 

 

 

 

 

Black

 

 

 

 

White

 

 

White

 

 

Ignition

 

 

2

 

Control

 

 

1

Black

 

 

3

4

 

 

 

 

 

 

 

5

6

 

Orange

 

 

7

8

 

Green

 

 

 

 

 

 

Relay

 

 

 

 

 

 

 

Blue

Ignitor

 

 

Blue

 

Thermal Switch

 

 

 

 

Blue

 

 

 

 

 

 

Thermocouple

 

 

Auto Control

 

 

 

 

 

 

 

 

 

 

Valve

Figure 14 - Electrical Connection Diagram

 

 

10

Image 10
Contents Unpacking DescriptionCombustion are vented into the area being heated General Safety Information Dayton Operating Instructions and Parts ManualSpecifications Product Identification Product IdentificationTheory of Operation Propane SupplyOperation InstallationVentilation To Start HeaterStorage MaintenanceService Procedures To Stop HeaterReplace base tray FANSpark Transformer Attach ignitor wireRemove ignitor from rear head IgnitorWiring Diagram Accessories100,000 BUT/HR Model Location Troubleshooting ChartClean heater. See Maintenance, Bad spark transformerDaytonFor Repair Parts, Propanecall ModelRepair 3VG80Parts List Not shownNot a UPC