General Safety Information (Continued)

Locate heater on stable and level surface if heater is hot or operating.

Never block air inlet (rear) or air outlet (front) of heater.

Keep heater away from strong drafts, wind, water spray, rain, or dripping water.

Never operate heater while unat- tended.

Keep children and animals away from heater.

Never move, handle, or service a hot or operating heater. Severe burns may result. You must wait 15 minutes after turning heater off.

To prevent injury, wear gloves when handling heater.

Never attach duct work to heater.

Do not alter heater. Keep heater in its original state.

Do not use heater if altered.

Turn off propane supply to heater and unplug when not in use.

Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.

Specifications

Output Rating

65,000 Btu/Hr

85,000 Btu/Hr

100,000 Btu/Hr

Fuel

Propane Vapor Only

Propane Vapor Only

Propane Vapor Only

Fuel Consumption

3.0 Pounds/Hr (0.7 Gallons/Hr)

3.9 Pounds/Hr (0.93 Gallons/Hr)

4.6 Pounds/Hr (1.1 Gallons/Hr)

Hot Air Output (CFM Approx.)

475

475

475

Regulator Outlet Pressure

Factory Preset

Factory Preset

Factory Preset

Manifold Pressure

10.0" WC

10.0" WC

10.0" WC

Max. Supply Pressure to Reg.

Tank Pressure

Tank Pressure

Tank Pressure

Min. Supply Pressure to Reg.

10 psi

10 psi

10 psi

(for purposes of input adjustment)

 

 

 

Electric Input

120 V 60 Hz

120 V 60 Hz

120 V 60 Hz

Amps

2.9

2.9

2.9

Ignition

Continuous Electronic

Continuous Electronic

Continuous Electronic

Ignitor Gap

Minimum: 0.13"

Minimum: 0.13"

Minimum: 0.13"

 

Maximum: 0.15"

Maximum: 0.15"

Maximum: 0.15"

Motor RPM

3,200, 1/10 HP

3,200, 1/10 HP

3,200 , 1/10 HP

Heater Weight

18 Lb

18 Lb

18 Lb

Shipping Weight

24 Lb

24 Lb

24 Lb

Dimensions

261/4"L x 9"H x 151/2"W (Heater)

261/4"L x 9"H x 151/2"W (Heater)

261/4"L x 9"H x 151/2"W (Heater)

 

281/2"L x 121/2"H x 17"W (Carton)

281/2"L x 121/2"H x 17"W (Carton)

281/2"L x 121/2"H x 17"W (Carton)

®

3

Version B - For Reduction

G016.J

Image 3
Contents Description UnpackingCombustion are vented into the area being heated Dayton Operating Instructions and Parts Manual General Safety InformationSpecifications Product Identification Product IdentificationPropane Supply Theory of OperationTo Start Heater InstallationVentilation OperationTo Stop Heater MaintenanceService Procedures StorageFAN Replace base trayIgnitor Attach ignitor wireRemove ignitor from rear head Spark TransformerAccessories Wiring Diagram100,000 BUT/HR Model Bad spark transformer Troubleshooting ChartClean heater. See Maintenance, LocationDaytonFor Repair Parts, Propanecall Not shown ModelRepair 3VG80Parts ListNot a UPC