Desa FSVYD18P To Turn OFF GAS To Appliance, Manual Lighting Procedure, Optional Remote Operation

Page 15

OWNER’S MANUAL

OPERATING

HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Set selector switch in the OFF posi- tion to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.

Turn control knob clockwise

 

to the PILOT position.

2.

Use remote control manual OFF button.

3.

Set remote selector switch in the OFF

For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position. NOTE: The burners may light if hand-held remote ON button was on when remote selector switch was last turned off. You can now turn the burners on and off with the hand- held remote control unit.

IMPORTANT: Do not leave the re- mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand held remote control unit for up to 3 sec- onds to assure proper operation.

GHRC Series Operation

2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

GHRCTA Series Operation

b.Press the AUTO/ON/OFF button on the hand-held remote control (see Fig- ure 28). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

position.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-

 

ing Instructions, page 14.

2.

Depress control knob and light pilot

 

with match.

3.

Keep control knob pressed in for 30

 

seconds after lighting pilot. After 30

 

seconds, release control knob. Now

Flame Adjustment Knob

 

 

 

 

 

 

 

 

Control Knob in

IH

 

 

PIL

On Position

ON

 

F

O

 

O

F

T

 

OFF

 

O

 

 

 

 

 

 

N

 

REMOTE

 

 

 

 

LO

 

 

 

 

Remote Selector Switch in Remote

Position (Optional Remote Control)

Figure 27 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

follow steps 9 through 11, page 14.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 33). Follow instructions included with the remote control.

Thermostat Control Operation

Shows Temperature Setting

The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected

Increases Room

Temperature in AUTO

Mode

Decreases Room

Temperature in AUTO

Mode

Turns Burners On or Off and Allows You to Choose the Auto Setting

(Optional GHRCTA Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween WARMER and COOLER. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Figure 28 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)

Continued

104462

15

Image 15
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Stove HeaterDesa International VENT-FREE PROPANE/LP GAS Stove Heater Safety InformationProduct Features Product IdentificationLocal Codes Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingVent-Free Operation Only InstallationCheck GAS Type Clearances to CombustiblesStove bottom Stove Cavity AssemblySheraton Models Amity and Townsend ModelsAttaching Stove Door Appearance May Vary Depending on Model Fastening Heater Base to Stove Drop Bottom Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections SVYD18PR and FSVYD18PR Remote-Ready Models For Your Safety Read Before LightingOperating Heater Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation SVYD18P and FSVYD18P Manual-Variable Control Models Variable Control OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceSpecifications Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Top SVYD18PR FSVYD18PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListSVYD18P FSVYD18P KEY Part Description QTY Amity SCIVF* Series PSCIVF* Series Indicates Color SuffixDesignation Indicates Color Suffix Designation Sheraton NSCIVF* Series Parts List Series TownsendFC* and PFC* Series *Indicates Color Suffix Designation Parts Under Warranty Replacement PartsWiring Diagram Service HintsAccessories Warranty Information

FSVYD18P specifications

Desa FSVYD18P is an innovative, high-performance appliance designed to enhance various environments, whether in commercial settings, industrial applications, or even advanced home use. This model stands as a testament to the forward-thinking technology and robust features that define modern equipment.

One of the standout attributes of the FSVYD18P is its energy efficiency. Built with the latest in energy-saving technology, it minimizes power consumption without sacrificing performance. The optimized design ensures that it efficiently uses resources, catering to eco-conscious consumers and businesses alike. This feature not only contributes to lower utility bills but also supports sustainable practices.

In terms of functionality, the FSVYD18P is equipped with a state-of-the-art control system. The intuitive interface allows users to easily navigate settings and customize operations to fit specific needs. This adaptability is particularly important in environments where demands shift frequently, making it a versatile choice for diverse applications.

Durability is a key characteristic of the FSVYD18P. Designed using high-quality materials, this appliance can withstand the rigors of everyday use. Whether in a bustling commercial kitchen or an industrial workspace, the robust construction ensures longevity and reliability, reducing the need for frequent repairs or replacements.

The FSVYD18P also integrates advanced technologies that enhance its overall performance. Features such as smart sensors allow for real-time monitoring of performance parameters, ensuring that the appliance operates optimally. These sensors can automatically adjust settings based on usage patterns, further enhancing efficiency and user convenience.

Safety is another critical aspect of the FSVYD18P. The appliance incorporates multiple safety mechanisms that prevent malfunctions and ensure safe operation under various conditions. This commitment to safety not only protects users but also extends the life of the appliance.

Overall, Desa FSVYD18P encapsulates a rich blend of advanced technology, user-friendly features, and durable design. Its emphasis on energy efficiency, adaptability, and safety make it an ideal solution for those seeking high-quality performance in their equipment. This appliance is a reliable companion in achieving both operational excellence and environmental responsibility, making it a standout choice in its category.