Desa FSVYD18P installation manual Stove Cavity Assembly, Stove bottom

Page 8

DESA INTERNATIONAL

VENT-FREE PROPANE/LP GAS STOVE HEATER

INSTALLATION

Continued

STOVE CAVITY ASSEMBLY

1.

Lift off corrugated box enclosing stove

 

body crating.

2.

Remove all screws fastening the wood

 

frame enclosure. Spread wood frame

 

open and lift away from plastic-bagged

 

stove body. The bottom pieces of pal-

Bolt

Product

Back Stove Panel

Identification Label

 

 

let wood will remain bolted to the stove

 

body.

3.

Remove plastic bag from stove body.

4.

Remove back panel from stove (see

 

Figure 5). Use an adjustable wrench or

 

a 10 mm socket. Remove six (6) bolts

 

and washers. Keep bolts and washers

 

to reattach back panel later.

5.

Remove all contents from inside stove

 

cavity. Contents include:

(1) - Stove bottom

(4)- Legs (Amity™ and Townsend™ models include leg leveler bolts)

Figure 5 - Removing Back Panel

Top of Stove Unit

Front of

Stove Unit

Drop Cloth/

Blanket

Front of

Stove UnitTop of

Stove

Unit

Pallet Wood

Bolted to

Stove Body

Bottom

(1)- Bottom door

(1)- Top grate

(1)- Hardware kit bag with fasteners

6.Carefully lay stove body on back to attach bottom components to stove body (see Figure 6). Rest stove on drop cloth or blanket to avoid scratching stove edges.

7.Remove remaining pallet wood at- tached to bottom of stove body (see Figure 7). Use an adjustable wrench to remove bolts.

Figure 6 - Laying Down Stove On Side (Stove Style May Vary Depending on Model)

Front

Bolt

Pallet

Wood

 

Bottom Of

Stove Unit

Pallet

Wood

Figure 7 - Removing Pallet Wood From The Bottom of The Stove

8

104462

Image 8
Contents VENT-FREE PROPANE/LP GAS Stove Heater What to do if YOU Smell GASSafety Information Desa International VENT-FREE PROPANE/LP GAS Stove HeaterLocal Codes Product FeaturesProduct Identification AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Check GAS TypeClearances to Combustibles Vent-Free Operation OnlyStove Cavity Assembly Stove bottomAmity and Townsend Models Sheraton ModelsAttaching Stove Door Appearance May Vary Depending on Model Installing GAS LOG Heater Into Stove Fastening Heater Base to Stove Drop BottomConnecting to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions SVYD18PR and FSVYD18PR Remote-Ready ModelsOptional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Variable Control Operation SVYD18P and FSVYD18P Manual-Variable Control ModelsInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning and Maintenance SpecificationsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Illustrated Parts Breakdown SVYD18PR FSVYD18PRParts List KEY Part Number Description QTYSVYD18P FSVYD18P KEY Part Description QTY Designation Amity SCIVF* Series PSCIVF* SeriesIndicates Color Suffix Indicates Color Suffix Designation Sheraton NSCIVF* Series Parts List Townsend SeriesFC* and PFC* Series *Indicates Color Suffix Designation Replacement Parts Wiring DiagramService Hints Parts Under WarrantyAccessories Warranty Information

FSVYD18P specifications

Desa FSVYD18P is an innovative, high-performance appliance designed to enhance various environments, whether in commercial settings, industrial applications, or even advanced home use. This model stands as a testament to the forward-thinking technology and robust features that define modern equipment.

One of the standout attributes of the FSVYD18P is its energy efficiency. Built with the latest in energy-saving technology, it minimizes power consumption without sacrificing performance. The optimized design ensures that it efficiently uses resources, catering to eco-conscious consumers and businesses alike. This feature not only contributes to lower utility bills but also supports sustainable practices.

In terms of functionality, the FSVYD18P is equipped with a state-of-the-art control system. The intuitive interface allows users to easily navigate settings and customize operations to fit specific needs. This adaptability is particularly important in environments where demands shift frequently, making it a versatile choice for diverse applications.

Durability is a key characteristic of the FSVYD18P. Designed using high-quality materials, this appliance can withstand the rigors of everyday use. Whether in a bustling commercial kitchen or an industrial workspace, the robust construction ensures longevity and reliability, reducing the need for frequent repairs or replacements.

The FSVYD18P also integrates advanced technologies that enhance its overall performance. Features such as smart sensors allow for real-time monitoring of performance parameters, ensuring that the appliance operates optimally. These sensors can automatically adjust settings based on usage patterns, further enhancing efficiency and user convenience.

Safety is another critical aspect of the FSVYD18P. The appliance incorporates multiple safety mechanisms that prevent malfunctions and ensure safe operation under various conditions. This commitment to safety not only protects users but also extends the life of the appliance.

Overall, Desa FSVYD18P encapsulates a rich blend of advanced technology, user-friendly features, and durable design. Its emphasis on energy efficiency, adaptability, and safety make it an ideal solution for those seeking high-quality performance in their equipment. This appliance is a reliable companion in achieving both operational excellence and environmental responsibility, making it a standout choice in its category.