Desa Variable Control Operation, SVYD18P and FSVYD18P Manual-Variable Control Models

Page 16

DESA INTERNATIONAL

VENT-FREE PROPANE/LP GAS STOVE HEATER

OPERATING

HEATER

Continued

In the AUTO mode, the thermostat in the hand-held remote unit con- trols the room temperature. To in- crease the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every minute in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.

IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

LIGHTING

INSTRUCTIONS

SVYD18P and FSVYD18P Manual-Variable Control Models

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell.Thiswillonlylastafewhours.

1.STOP! Read the safety information page 14, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clock-

wise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 14, column 1 . If you don’t smell gas, go to the next step.

5.Slightly depress and turn control

knob counterclockwise C-clockwiseto the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner (see Figure 18, page 11). If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 17.

Ignitor Button

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 29 - Control Knob and Ignitor Button Location

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 30 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Slightly depress and turn control

knob counterclockwise C-clockwiseto the HIGH position. The burner should light. Set control knob to any heat level between HIGH and LO.

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in in- creased heating comfort.

WARNING: Do not operate heater between PILOT and HIGH positions.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock-

wise Clockwise to the HIGH position.

2.Turn the control knob clockwise Clockwise to the PILOT position.

3.Press in control knob and turn clock-

wise Clockwise to the OFF Position.

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise Clockwise to the HIGH position.

2.Press in and turn control knob clock-

wise Clockwise to the PILOT position.

16

104462

Image 16
Contents VENT-FREE PROPANE/LP GAS Stove Heater What to do if YOU Smell GASSafety Information Desa International VENT-FREE PROPANE/LP GAS Stove HeaterProduct Identification Product FeaturesLocal Codes AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Check GAS TypeClearances to Combustibles Vent-Free Operation OnlyStove Cavity Assembly Stove bottomAmity and Townsend Models Sheraton ModelsAttaching Stove Door Appearance May Vary Depending on Model Installing GAS LOG Heater Into Stove Fastening Heater Base to Stove Drop BottomConnecting to GAS Supply Installation Items NeededPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions SVYD18PR and FSVYD18PR Remote-Ready ModelsTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Variable Control Operation SVYD18P and FSVYD18P Manual-Variable Control ModelsInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning and Maintenance SpecificationsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Illustrated Parts Breakdown SVYD18PR FSVYD18PRParts List KEY Part Number Description QTYSVYD18P FSVYD18P KEY Part Description QTY Indicates Color Suffix Amity SCIVF* Series PSCIVF* SeriesDesignation Indicates Color Suffix Designation Sheraton NSCIVF* Series Parts List Townsend SeriesFC* and PFC* Series *Indicates Color Suffix Designation Replacement Parts Wiring DiagramService Hints Parts Under WarrantyAccessories Warranty Information

FSVYD18P specifications

Desa FSVYD18P is an innovative, high-performance appliance designed to enhance various environments, whether in commercial settings, industrial applications, or even advanced home use. This model stands as a testament to the forward-thinking technology and robust features that define modern equipment.

One of the standout attributes of the FSVYD18P is its energy efficiency. Built with the latest in energy-saving technology, it minimizes power consumption without sacrificing performance. The optimized design ensures that it efficiently uses resources, catering to eco-conscious consumers and businesses alike. This feature not only contributes to lower utility bills but also supports sustainable practices.

In terms of functionality, the FSVYD18P is equipped with a state-of-the-art control system. The intuitive interface allows users to easily navigate settings and customize operations to fit specific needs. This adaptability is particularly important in environments where demands shift frequently, making it a versatile choice for diverse applications.

Durability is a key characteristic of the FSVYD18P. Designed using high-quality materials, this appliance can withstand the rigors of everyday use. Whether in a bustling commercial kitchen or an industrial workspace, the robust construction ensures longevity and reliability, reducing the need for frequent repairs or replacements.

The FSVYD18P also integrates advanced technologies that enhance its overall performance. Features such as smart sensors allow for real-time monitoring of performance parameters, ensuring that the appliance operates optimally. These sensors can automatically adjust settings based on usage patterns, further enhancing efficiency and user convenience.

Safety is another critical aspect of the FSVYD18P. The appliance incorporates multiple safety mechanisms that prevent malfunctions and ensure safe operation under various conditions. This commitment to safety not only protects users but also extends the life of the appliance.

Overall, Desa FSVYD18P encapsulates a rich blend of advanced technology, user-friendly features, and durable design. Its emphasis on energy efficiency, adaptability, and safety make it an ideal solution for those seeking high-quality performance in their equipment. This appliance is a reliable companion in achieving both operational excellence and environmental responsibility, making it a standout choice in its category.