Enviro C-10985 Troubleshooting, Stove will not start, Stove will not operate when hot

Page 22

Troubleshooting

DO NOT:

Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

Do not remove from the firebox any screws without penetrating oil lubrication.

WHAT TO DO IF:

1.The stove will not start.

2.The stove will not operate when hot.

3.The exhaust blower will not function normally.

4.Light # 2 on Heat output bar flashing.

5.Auger light flashes but auger motor does not turn at all

6.The 200 °F (93 °C) high limit temperature sensor has tripped.

7.The convection blower will not function normally.

8.Igniter- the pellets will not light.

9.Control settings (Heat Level) has no effect on the fire.

10.The stove keeps going out.

*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers.

1. The stove will not start.

üMake sure the stove is plugged in and the wall outlet is supplying power..

üIf the Control Board has been placed in the ON /OFF thermostat mode, then turn the thermostat up to call for heat.

üCheck the Heat Level Indicator. - If the # 2 light is flashing (see the # 2 light is flashing) üCheck the fuses on the circuit board (see “Troubleshooting - Fuses”).

üIf the unit still does not start, contact your local service dealer for service.

2. The stove will not operate when hot.

üCheck the Heat Level Indicator if a fire is not detected, or if the fire has gone out the #3 light will flash because the Exhaust Temperature Sensor’s contacts have opened.

üCheck the hopper for fuel.

üIncorrect air damper setting. - Excessive air may consume the fire too quickly before the next drop of fuel, leaving completely unburned fuel in the burn pot liner. - Insufficient air will cause build up, further restricting the air flow through the Burn Pot Liner. This in turn will cause the fuel to burn cold and very slowly. Fuel may build up and smother the fire. In this case clean the burn pot. (NOTE: unit may require a change to the vent system or installation of fresh air to correct Air to Fuel ratio problems).

üCombustion Blower failure. - The Combustion Blower is not turning fast enough to generate the proper vacuum in the fire box. Visual Check – is the blower motor turning.

üCheck the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 82 V. with a line voltage >114 V AC.

üCheck Vacuum levels in the exhaust channel by bypassing the Vacuum Switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge (readings must be above .10” W.C. on low fire).

If the motor fails to reach a 0.10” W.C. readings, then replace the Combustion Blower.

22

Image 22
Contents Mini Table of Contents Introduction Introduction Installation Screws to take out to remove stove from PalletDimensions of Mini 91.5 cm Crawlspace, narrow Walkway Closely Fresh AIR Intake 75mm Wall thimble Manufactured by pellet vent manufacturer Allows installation with the least amount Is the recommended installation set up Place a non-combustible hearth pad where Refer to Figures 17 Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit Sheathing To install the Optional slider damper rod, remove the left Special Notes Installing the Panels Kit ComponentsInstalling Hopper Lid Installing Hopper LidStove will not operate when hot TroubleshootingStove will not start Exhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Ignitor- the pellets will not light Control settings Heat Level has no effect on the fireConvection blower will not function normally Stove keeps going outWiring Diagram 5V DCParts List Reference Description Part NumberParts List Parts Diagram Components Parts Diagram Steel Warranty For the do-it-yourself IndividualInstallation Data Sheet Name of Owner Address

C-10985 specifications

Enviro C-10985 is a cutting-edge environmentally friendly chemical formulation specifically designed for industrial cleaning and degreasing applications. Its introduction marks a significant advancement in sustainable chemical solutions, catering to industries that prioritize safety and environmental impact.

One of the main features of Enviro C-10985 is its non-toxic composition. Unlike traditional solvents that often contain hazardous volatile organic compounds (VOCs), this innovative formula is derived from renewable sources, making it safe for users and the environment. The low-VOC content minimizes air pollution and reduces health risks associated with exposure to harmful chemicals, aligning with stringent safety regulations and guidelines.

The technology behind Enviro C-10985 incorporates advanced surfactant systems that enhance its cleaning efficacy. These surfactants are designed to penetrate and lift grease, oil, and dirt from various surfaces. The product can be employed on metals, plastics, and other materials, ensuring versatility in industrial applications. The biodegradable nature of these surfactants further emphasizes the product's eco-friendliness, as it breaks down without leaving harmful residues.

Enviro C-10985 is also formulated to be user-friendly. It comes in a concentrated solution that can be diluted to meet the specific needs of various cleaning tasks, reducing both waste and transportation costs. The product’s formulation is compatible with various application methods, including pressure washing, spray application, and manual cleaning, making it suitable for a wide range of operational contexts.

Another characteristic of Enviro C-10985 is its performance at varying temperatures. It retains its cleaning power in both cold and hot water, making it adaptable to different cleaning scenarios. This feature is particularly beneficial in industries where temperature controls vary significantly.

Additionally, Enviro C-10985 is designed to mitigate corrosion and protect surfaces during the cleaning process, contributing to the longevity of equipment and machinery. The formulation includes corrosion inhibitors that safeguard metal surfaces from rust and degradation, ensuring consistent performance over time.

In conclusion, Enviro C-10985 is an exemplary solution for businesses seeking effective, safe, and environmentally responsible cleaning products. Its unique features, advanced technology, and compatibility with multiple applications make it an invaluable asset in modern industrial cleaning regimes.