Enviro C-10985 technical manual Installation, Screws to take out to remove stove from Pallet

Page 5

Installation

DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:

1. Check clearances to combustibles.

2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace.

3. Do not install the stove in a bedroom.

4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (must be lined if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional area). An interior vent can be used with approved pipe passing through the ceiling and roof.

5. Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation.

6. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the nearest electrical outlet.

REMOVING PELLET STOVE FROM PALLET:

 

1.

Remove the right and left hand cabinet sides by

 

loosening the three (3) T-20 Torx screws on the back

 

of the each panel.

2.

Remove the screw located on the front of the cabinet

 

side, below the louvers and loosen the screw behind

 

the ash door.

3.

Using a 5/16” socket of flat head screwdriver, remove

 

the three (3) wood screws that are holding the

 

bottom of the stove to the pallet. There is one (1)

 

screw behind each side panel and one (1) at the back

 

behind the back grill.

4.

Install the four (4) leveling legs into the nuts in the

 

base.

5.

Close the side panels.

Figure 1: Screws to take out to remove stove from

 

pallet.

 

5

Image 5
Contents Mini Table of Contents Introduction Introduction Screws to take out to remove stove from Pallet InstallationDimensions of Mini 91.5 cm Crawlspace, narrow Walkway Closely Fresh AIR Intake 75mm Wall thimble Manufactured by pellet vent manufacturer Allows installation with the least amount Is the recommended installation set up Place a non-combustible hearth pad where Refer to Figures 17 Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit Sheathing To install the Optional slider damper rod, remove the left Special Notes Kit Components Installing the PanelsInstalling Hopper Lid Installing Hopper LidStove will not start TroubleshootingStove will not operate when hot Light # 2 on Heat output bar flashing 200 F 93 C high limit temperature sensor has trippedExhaust motor will not function normally Convection blower will not function normally Control settings Heat Level has no effect on the fireIgnitor- the pellets will not light Stove keeps going out5V DC Wiring DiagramReference Description Part Number Parts ListParts List Parts Diagram Components Parts Diagram Steel For the do-it-yourself Individual WarrantyName of Owner Address Installation Data Sheet

C-10985 specifications

Enviro C-10985 is a cutting-edge environmentally friendly chemical formulation specifically designed for industrial cleaning and degreasing applications. Its introduction marks a significant advancement in sustainable chemical solutions, catering to industries that prioritize safety and environmental impact.

One of the main features of Enviro C-10985 is its non-toxic composition. Unlike traditional solvents that often contain hazardous volatile organic compounds (VOCs), this innovative formula is derived from renewable sources, making it safe for users and the environment. The low-VOC content minimizes air pollution and reduces health risks associated with exposure to harmful chemicals, aligning with stringent safety regulations and guidelines.

The technology behind Enviro C-10985 incorporates advanced surfactant systems that enhance its cleaning efficacy. These surfactants are designed to penetrate and lift grease, oil, and dirt from various surfaces. The product can be employed on metals, plastics, and other materials, ensuring versatility in industrial applications. The biodegradable nature of these surfactants further emphasizes the product's eco-friendliness, as it breaks down without leaving harmful residues.

Enviro C-10985 is also formulated to be user-friendly. It comes in a concentrated solution that can be diluted to meet the specific needs of various cleaning tasks, reducing both waste and transportation costs. The product’s formulation is compatible with various application methods, including pressure washing, spray application, and manual cleaning, making it suitable for a wide range of operational contexts.

Another characteristic of Enviro C-10985 is its performance at varying temperatures. It retains its cleaning power in both cold and hot water, making it adaptable to different cleaning scenarios. This feature is particularly beneficial in industries where temperature controls vary significantly.

Additionally, Enviro C-10985 is designed to mitigate corrosion and protect surfaces during the cleaning process, contributing to the longevity of equipment and machinery. The formulation includes corrosion inhibitors that safeguard metal surfaces from rust and degradation, ensuring consistent performance over time.

In conclusion, Enviro C-10985 is an exemplary solution for businesses seeking effective, safe, and environmentally responsible cleaning products. Its unique features, advanced technology, and compatibility with multiple applications make it an invaluable asset in modern industrial cleaning regimes.