Enviro Evolution, C-10825 owner manual Through vent hole, Exterior Blower Kit

Page 22

Installation

EXTERIOR MOUNTED EXHAUST BLOWER:

The EF5 can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface.

Choose a location for your stove that meets the requirements stated in your manual and allows installation with the least amount of interference with house framing, plumbing, wiring, etc.

Included in the Exterior Mounted Exhaust Blower Kit are: 1 - Exhaust blower housing box.

1 - Blower cover plate.

1 - Hardware bag

Figure 20: Exterior Blower Kit.

 

1.

Remove the left hand cabinet side by removing the two

 

 

(2) screws down the front. Loosen the three screws on the

 

 

back of the cabinet side and remove panel.

 

2.

Loosen the six (6) screws that hold the back grill in place.

 

 

Lift the back grill off the screws.

 

3.

Disconnect the Exhaust blower wires from the wire

 

 

harness. Remove the exhaust blower motor from the

 

 

housing; six (6) screws. Cover hole in housing with cover

 

 

plate provided (see Figure 21).

Figure 21: Exterior Blower Kit.

4. Remove the cover from the exhaust blower housing box.

 

5.

Install the exhaust blower housing box into the pipe placed

 

 

through the wall thimble, seal with high temperature

 

 

silicone. Fasten the box to the wall with (4) four screws,

 

 

seal edges of box to wall with clear silicone.

 

6.

Drill a hole through the wall thimble plate for the electrical

 

 

wires. Pass the armored cable through the wall thimble.

 

 

Use the strain relief provided. Do not pass cable

 

 

through vent hole.

 

7. Install the Exhaust Blower motor into the external exhaust

 

 

blower housing box. Make the electrical connections to the

 

 

wire harness and exhaust blower.

 

8.

Replace the cover on the Exhaust Box and the back grill of

 

 

the stove and ensure the screws are tightened down.

Figure 22: Exterior Blower Kit cut-through.

9.

Install vertical pipe as instructed in appropriate section.

 

 

22

Image 22
Contents Evolution Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Reasons WHY the Unit Overheated Operating InstructionsThermostat / Switch Mode Initial START-UP See aboveBurner POT and Liner 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Heat Exchanger Tubes 2-3 daysFresh AIR Intake biannually Door Glass Cleaning 2-3 daysASH PAN weekly Exhaust Passages biannuallyDoor Glass Replacement Post Season CLEAN-UPCleaning Plated Surfaces Brick PanelInstallation Screws to take out to remove stove from palletDimensions of EF5 Maximum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Horizontal Exhaust Through Wall Installation Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 If you wish to adjust the slider damper externally not REQUIRED, please follow the instructions belowSlider Damper Located Behind Left Side panel. To open Special NotesDo not TroubleshootingStove will not operate when hot What to do ifExhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Ignitor- the pellets will not light Control settings Heat Level has no effect on the fireConvection blower will not function normally Stove keeps going outWiring Diagram 5V DCParts List Reference Number Description Part NumberParts List Parts Diagram Components SteelDiagramParts To the Dealer WarrantyTo the Distributor Installation Data Sheet Name of Owner Address