Enviro C-10825, Evolution owner manual If you wish to adjust the slider damper externally not

Page 25

Installation

THERMOSTAT INSTALLATION:

A) HI / LOW:

When the jumper is placed on only one of the J9 pins, then the control board is in a HI / LOW mode of thermostat operation (factory setting).

B) ON / OFF:

If both pins of J9 are jumped (covered), the control board is in an ON / OFF mode of thermostat operation.

Remove jumper wire and install thermostat wires here

Figure 26: Circuit Board.

This control board can be placed into two different modes: When the jumper J9 is not jumped then the control board is in a HI / LOW mode operation. If the control board is placed with J9 jumped then the control board is in a ON / OFF mode of operation. In the ON /OFF thermostat mode, the unit will shut OFF when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go through an ignition sequence once again and relight.

1.Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area.

2.Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.

If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator. If the heating load is not great enough when the stove is on low, the high limit switch will turn the stove off and the switch will have to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found behind the control panel. Avoid setting off the high limit switch.

OPTIONAL SLIDER/DAMPER INSTALLATION:

 

NOTE: NOT FOR USE IN GERMANY

Slider damper

 

If you wish to adjust the slider damper externally (NOT

rod and knob

REQUIRED), please follow the instructions below.

 

 

 

 

7/16" Nut

 

 

 

7/16" Clinching Nut

 

 

 

Slider damper plate

 

 

 

Figure 27: Slider/Damper Assembly.

Slider/

1.

To install the OPTIONAL slider damper rod, remove the left cabinet

 

side and

locate the slider damper plate. Install the 7/16” inch nut

Damper

 

Knob

 

onto the slider damper rod, thread all the way to the end of the

 

 

threads on rod.

 

2.

Slide rod through the hole in the slider damper plate and install the

 

 

7/16” clinching nut onto the rod and tighten completely onto the slider

 

 

damper plate.

Figure 28: Slider/Damper Knob.

3. Re-install the cabinet side. Install the black knob on the end of the

 

 

rod. Check slider damper for smooth operation.

25

Image 25
Contents Evolution Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedInitial START-UP See above Thermostat / Switch ModeTools Required to Clean Unit Routine Cleaning and MaintenanceBurner POT and Liner 2-3 days Heat Exchanger Tubes 2-3 daysASH PAN weekly Door Glass Cleaning 2-3 daysFresh AIR Intake biannually Exhaust Passages biannuallyCleaning Plated Surfaces Post Season CLEAN-UPDoor Glass Replacement Brick PanelScrews to take out to remove stove from pallet InstallationDimensions of EF5 Maximum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Horizontal Exhaust Through Wall Installation Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 REQUIRED, please follow the instructions below If you wish to adjust the slider damper externally notSpecial Notes Slider Damper Located Behind Left Side panel. To openStove will not operate when hot TroubleshootingDo not What to do ifExhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Convection blower will not function normally Control settings Heat Level has no effect on the fireIgnitor- the pellets will not light Stove keeps going out5V DC Wiring DiagramReference Number Description Part Number Parts ListParts List Parts Diagram Components SteelDiagramParts To the Dealer WarrantyTo the Distributor Name of Owner Address Installation Data Sheet