Enviro C-10825, Evolution owner manual Thermostat / Switch Mode, Initial START-UP See above

Page 7

Operating Instructions

OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR.

MANUAL MODE:

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“OPERATING INSTRUCTIONS; STOVE CONTROLS”).

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10

-15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed at this time to change the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control button. When the air jacket reaches 160 °F (71 °C) the convection blower will come ON High, cooling the unit. For the best efficiency and to prevent cycling, the convection blower should be left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “OPERATING INSTRUCTIONS; STOVE CONTROLS - CIRCUIT BOARD”).

THERMOSTAT / SWITCH MODE:

INITIAL START-UP: See above

OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will take control of the settings. The stove will drop down to a low burn until the thermostat contacts close

again. This low burn setting can be adjusted for different fuel qualities (see “OPERATING INSTRUCTIONS;

STOVE CONTROLS - CIRCUIT BOARD”). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in manual mode (see above). When the thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.

DO NOT unplug unit while Combustion fan is operating.

This may lead to smoke escaping from the stove.

7

Image 7
Contents Evolution Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedInitial START-UP See above Thermostat / Switch ModeHeat Exchanger Tubes 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burner POT and Liner 2-3 daysExhaust Passages biannually Door Glass Cleaning 2-3 daysASH PAN weekly Fresh AIR Intake biannuallyBrick Panel Post Season CLEAN-UPCleaning Plated Surfaces Door Glass ReplacementScrews to take out to remove stove from pallet InstallationDimensions of EF5 Maximum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Crawlspace, narrow Walkway Closely Exhaust Fresh Air Intake Horizontal Exhaust Through Wall Installation Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 REQUIRED, please follow the instructions below If you wish to adjust the slider damper externally notSpecial Notes Slider Damper Located Behind Left Side panel. To openWhat to do if TroubleshootingStove will not operate when hot Do notExhaust motor will not function normally 200 F 93 C high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts ListParts List Parts Diagram Components SteelDiagramParts To the Dealer WarrantyTo the Distributor Name of Owner Address Installation Data Sheet