Enviro 50-830 owner manual Do not Place Unburned or RAW Pellet Fuel in ASH PAN

Page 11

Routine Cleaning and Maintenance

ASH PAN AND DOOR GASKETS (weekly)

After extended use the gasketing may come loose. To repair this, glue the gasketing on using high- temperature fiberglass gasket glue available from your local ENVIRO dealer. This is important to maintain an airtight assembly.

ASH PAN (weekly)

The ash pan is located under the burner. Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality. Refer to “INTRODUCTION -

SAFETY WARNINGS AND RECOMMENDATIONS” for disposal of ashes.

Freestanding: To remove the ash pan, simply turn the knob and pull out towards the front.

Insert: To remove the ash pan open the door, remove the burn pot liner and the burn pot, then pull the ash pan out.

DO NOT PLACE UNBURNED OR RAW PELLET FUEL IN ASH PAN.

HEAT EXCHANGER TUBES (weekly)

Open the door and the rod is located under the unit top, in the center of the stove just behind the door (see Figure 7). This handle is to be pushed in and out a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run efficiently.

FRESH AIR INTAKE (season)

Tube cleaner rod

Figure 7: Heat Exchanger Tube Cleaner.

Inspect periodically to be sure that it is not clogged with any foreign materials.

EXHAUST VENT (season)

This vent should be cleaned every year or after two (2) tons of pellets. We recommend contacting your dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.

BLOWER MECHANISMS (season)

Unplug the stove then open the right and left side panels to access the two blowers. Vacuum all dust from motors. DO NOT lubricate the motors. Check gaskets and replace if needed.

ALL HINGES (season)

Check all the hinges on the unit to ensure proper movement.

11

Image 11
Contents Meridian Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel 32 1/2 826mm 24 7/8 24 3/4 632mm 629mm Circuit Board Control Panel Decal Operating InstructionsInitial START-UP See above Thermostat / Switch ModeSpecial Notes Slider / Damper Must be SET AT Time of InstallationBurn POT and Liner 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Door Glass Cleaning 2-3 daysDo not Place Unburned or RAW Pellet Fuel in ASH PAN Firebox Panel Installation of firebox backingPost Season CLEAN-UP Cleaning Plated SurfacesFor the do-it-yourself Individual WarrantyTo the Distributor Name of Owner Address Installation Data Sheet

50-830 specifications

The Enviro 50-830 is an innovative and versatile vehicle designed to address the growing need for efficiency and environmental sustainability in public transportation. With a focus on reducing emissions and enhancing the passenger experience, this model is becoming increasingly popular among transit agencies around the globe.

One of the standout features of the Enviro 50-830 is its advanced propulsion system. Equipped with a powerful yet eco-friendly engine, the vehicle demonstrates a commitment to reducing the carbon footprint while maintaining optimal performance. The engine complies with stringent emission standards, ensuring that it meets or exceeds environmental regulations.

The Enviro 50-830 also incorporates cutting-edge technologies designed for both safety and comfort. It includes advanced driver assistance systems (ADAS) that enhance safety for passengers and pedestrians alike. Features such as collision avoidance, lane-keeping assistance, and adaptive cruise control provide drivers with the necessary support to navigate busy urban environments safely.

In addition to safety, passenger comfort is a top priority for the Enviro 50-830. The interior is thoughtfully designed to offer a spacious and welcoming atmosphere. High-backed, ergonomic seating ensures comfort during travel, while ample legroom and wide aisleways facilitate easy movement. The vehicle is also equipped with Wi-Fi connectivity, real-time arrival information displays, and USB charging ports to cater to the needs of modern commuters.

Durability and reliability are key characteristics of the Enviro 50-830. Built with high-quality materials, the vehicle is designed to withstand the rigors of daily service while requiring minimal maintenance. This not only protects the investment for transit agencies but also ensures consistent service for passengers.

Additionally, the Enviro 50-830 embraces a modular design that allows for easy customization to meet varying operational needs. Agencies can tailor the configuration of the seating, features, and technologies to suit their specific requirements while still benefiting from a robust and efficient platform.

Overall, the Enviro 50-830 stands out as a forward-thinking solution for public transportation. By integrating sustainable practices, advanced technology, and passenger-centered design, it is setting a new standard for the future of urban mobility. Transit agencies looking to modernize their fleet while promoting a greener environment will find the Enviro 50-830 to be an ideal choice.