Enviro 2100 owner manual Specifications, Model Freestanding

Page 9

Specifications

WOOD STOVE SPECIFICATIONS:

Model

2100 Freestanding

 

 

Width x Depth

24” x 30” (610 mm x 762 mm)

 

 

 

Height with pedestal or legs

33”

(838 mm)

 

 

 

Height of body

22”

(559 mm)

 

 

Fire box size (depth x width x height)

211⁄2” x 18” x 12” (546 mm x 457 mm x 305 mm)

 

 

 

Capacity

3.1 feet3

(0.0878 meter3)

* Approximate heating area

2100 feet2 (195.1 meter2)

**E.P.A. output rating

11,800 to 34,000 BTU/hour (3,455 to 9,956 watt)

 

 

*Duration on low burn

9 to 11 hours

 

 

Weight without bricks

414 pound (188 Kg)

 

 

Weight of bricks

103.2 pound (46.8 Kg)

 

 

E.P.A. Emissions

2.9 grams/hour (0.102 oz/hour)

 

 

 

* Figures Will Vary Considerably With Fuel And Conditions.

**E.P.A. output is calculated from a load of fir averaged from start until entirely consumed. The actual heat output with refueling is very much greater.

CERTIFICATION: these stoves have been tested and listed by Intertek (ITS) (WH) to standards CSA B366.2/ULC-S627, ULC-S628-M93, UL 1482-1994.

CLEARANCES TO COMBUSTIBLES - FREESTANDING:

MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*

 

 

With Single Wall Pipe

 

 

 

A

From side wall to side of unit

22” (559 mm)

B

From rear wall to back of unit

12” (305 mm)

C

From adjacent wall to corner of unit

8” (203 mm)

 

 

 

D

From side wall to collar

31” (787 mm)

 

 

 

E

From rear wall to collar

161⁄2” (419 mm)

 

 

 

F

From adjacent wall to collar

19” (483 mm)

 

 

 

G

† From front of unit to edge of hearth pad

18” (457 mm)

 

 

 

H

† From side/back of unit to edge of hearth pad

8” (203 mm)

 

 

 

CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed space, or through a floor, ceiling, wall, or partition, or any combustible construction.

FLOOR PROTECTION: If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE hearth pad.

 

 

 

�����

 

 

 

 

������

 

 

���� ����

 

����

 

 

 

����

 

�����

 

 

�������� ����

����

 

 

 

��������

 

 

 

 

9

Image 9
Contents Wood Stove Safety Precautions Table of Contents Operating Instructions Chimney or RUN Away Fire MaintenanceFuel Selection Building/Maintaining a FireFor Maximum Efficiency Refueling the StoveWhat is draft? Why can’t I get the fire lit?What type of wood is best to use as firewood? What does dry, seasoned wood mean?What can cause a poor draft? Model Freestanding SpecificationsInstallation Through with a minimum 9 229 mm air space between the outer Installation Outside AIR Total Bricks Glass is Broken Optional FAN Installation Parts List PartsDiagram Plating WarrantyInstallation Data Sheet