Harman Stove Company TL 300 manual Introduction, Appliance Certification, Model TL300

Page 4

Introduction

Thank you for purchasing the Harman TL300 Wood Stove. We are confident that you will enjoy the warmth and convenience of your Harman Stove for decades to come.

With the TL300 you will notice even heat throughout your home and long burn times. This is possible because of Harman’s special FireDome Non-Catalytic Combustion System, designed into the TL300 to promote clean burning and even heat output. This equates to unvarying heat over a longer period of time without the temperature peaks and valleys of other wood stoves. The FireDome continues Harman’s reputation of high efficiency while saving you the expense associated with catalytic stoves. The top load door makes adding wood easier and allows more wood to fit into the large firebox. You can view your beautiful fire through the extra large glass door. The glass stays cleaner because of the special IR coated glass and the exclusive Harman Air Wash System.

The Harman TL300 has an ash pan with its own ash door which allows removal of ashes while the stove is in operation. This means you can keep a fire all winter if you desire.

The Harman TL300 offers a cooking grill that can be placed in the top of the stove while in operation. This allows you to grill your favorite meats all year long even when the weather is not suitable for outside grilling. If you haven't already purchased the cooking grill, you can do so from your Authorized Harman Dealer.

Due to the fact that the TL300 is hot while in operation, gloves should be worn while tending to the fire.

For your reference, please copy your serial number from the label on your stove to the box below.

sERIAL nUMBER

Appliance Certification.

Model: TL300

Test Lab: Omni-Test Laboratories

Report #: 135-S-18-6

Type: Solid Fuel Fireplace Stove or Room Heater

Standard(s): UL 1482, UL 737, ULC-S627

Note: This appliance is also approved for installation into a shop.

 

LISTED SOLID FUEL FIREPLACE STOVE OR ROOM HEATER

 

 

 

 

 

 

8” (200 mm)

 

APPAREIL DE CHAUFFAGE OU POELE A COMBUSTIBLE SOLIDE

F

 

D

B

 

 

 

MODEL/MODELE: TL300

 

 

 

 

 

 

 

 

 

 

 

 

C

 

8”

8”

Report#/Rapport # 135-S-18-6

SERIAL NUMbER/NUMERO DE SERIE:

 

 

 

 

 

 

 

 

 

 

 

Tested to/Teste a: UL 1482, UL 737

 

 

 

E

 

 

A

 

200mm

200mm

Meets requirements of ULC S627-00/Selon les exigences de ULC S627-00

 

 

 

 

 

 

 

Certified for USA and Canada/Certifie pour les Etats-Unis et le Canada

Manufactured by / Fabriqué par:

 

 

 

 

 

 

18”

Room Heater, Solid Fuel Type, Also For Use In Mobile Homes In US only

 

 

 

 

 

 

PREVENT HOUSE FIRES: Install and use only in accordance with manufacturer’s installation

 

 

 

 

 

 

 

 

450 mm

 

 

 

 

 

 

 

 

16”

and operation instructions and local codes. In absence of any local codes, installation must meet

 

 

CLEARANCE TO COMBUSTIBLE SURFACES

DISTANCES MINIMALES DE SECURITE

Floor protection must be a non-combustible material. Must

minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for

 

 

precautions required for passing chimney through a combustible wall or ceiling.

 

 

A - Unit to Sidewall

20”

A - Entre le mur lateral et l’appareil

500 mm

also be placed under any horizontal sections of flue connector,

 

 

b - Unit to backwall

18”

b - Entre le mur arriereet l’appareil

450 mm

extending 2” (51mm) beyond the measurement of the pipe.

FOR USE WITH SOLID WOOD FUEL ONLY.

 

 

 

 

 

 

C - Chimney Connector to Sidewall

31”

C - Entre le tuyau et le mur lateral

775mm

Pour protéger le plancher, il faut sous le poêle un matériau.

Do NOT connect this stove to a chimney serving another appliance.

352 Mountain House Road

D - Chimney Connector to backwall

24”

D - Entre le tuyau et le mur arriere

600 mm

Qui doit aussi être placé sous les parties horizontales du tuyau

Flue connector pipe must be 6” diameter, minimum 24 MSG black or 26 MSG blue steel.

Halifax, PA 17032

(É.-U.)

E - Unit to Adjacent Wall

18”

E - Entre le mur adjacent et l’appareil

450 mm

de raccord à la cheminée et s’étendre à 51 mm (2 po) au-delà

Chimney must be factory built UL 103HT or masonry.

 

 

F - Chimney Connector to Adjacent Wall

27”

F - Entre le tuyau et le mur adjacent

675 mm

de la mesure du tuyau.

 

NOTE: Replace glass only with 5mm ceramic glass available from your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup

REFER TO MANUFACTURER’S INSTRUCTIONS FOR CLEARANCES WITH ADDITIONAL VENT CONFIGURATIONS.

 

 

may occur rapidly.

Veuillez vous référer au manuel d’instruction du manufacturier pour informations additionnels pour la configura-

 

 

 

DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, IT IS BEING OVERFIRED.

tion de la ventilation.

CAUTION:HOT WHILE IN OPERATION. DO

 

 

ATTENTION:CHAUD LORS DU FONCTIONNEMENT.

Respectez scrupuleusement les instructions du constructeur pour l’installation et l’utilisation.

Prevention des incendies:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Respectez les regles et normes applicables dans votre region. Dans tous les cas, l’installation devra

NE TOUCHEZ PAS L’APPAREIL.GARDEZ LES ENFANTS ET LES

NOT TOUCH. KEEP CHILDREN AND CLOTHING AWAY.

Reportez vous aux instructions du fabricant et aux regles locales pour les precautions necessaires

VÊTEMENTS ÉLOIGNÉS. TOUT CONTACT PEUT ENTRAÎNER

CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE

au minimum satisfaire aux exigences de NFPA 211 AUX Etats-Unis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lors du passage des tuyaux de fumee a travers un mur ou un plafond combustible. Controlez et

DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE

AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER

nettoyez frequemment la cheminee et les tuyaux de fumee selon les instructions du fabricant.

SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER

COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE

Ne pas raccorder ce poele a un conduit de fumee utilise pour un autre appareil.

ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART

AWAY FROM THIS APPLIANCE.

N’UTILISIXZ QUE DU BOIS EN BUCHES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Le tuyau de fumee doit avoir 6” de diametre minimum, et etre en acier de qualite 24 MSG noir ou

DE L’APPAREIL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26 MSG bleu.

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces

 

 

 

 

 

 

 

U.S. ENVIRONMENTAL PROTECTION AGENCY

Le conduit de fumee peut etre maconne ou de fabrication industrielle type ULC S629.

 

 

 

 

Certified to comply with July 1990 particulate emission standards.

d’origine américaine et pièces importées.

 

 

 

 

Nota: Ne remplacer la vitre qu’avec une vitre ceramique de 45 mm disponible chez votre fournisseur.

 

 

 

 

 

 

 

 

Date of Manufacture/Date de fabrication:

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.

 

 

 

 

 

 

 

 

Controlez et nettoyez frequemment la cheminee et les tuyaux de fumee. Dans certaines conditions

2011 2012 2013 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

d’utilization, des accumulations de cresote peuvent se produire rapidement.

CONSULTEX LES ADMINISTRATIONS ET ORGANISMES COMPETENTS POUR LA CONSTRUCTION ET LA PREVENTION DES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NE PAS SUR CHAUFFER - SI LE POELE OU LE TUYAU ROUGISSENT, VOUS SURCHAUFFEZ

INCEDIES AFIN DE RESPECTER LES REGLES DE SECURITE EN VIGUEUR.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4Harman TL300

Image 4
Contents Installation & Operating Manual Safety NoticeHarman TL300 Index Hearth & Home Technologies, IncIntroduction Appliance CertificationModel TL300 Report # 135-S-18-6Specifications Specifications Always wear fire retardant gloves When operating the stove Installation Parallel versus Corner InstallationsMobile Home Installation ClearancesInstallation/Clearances Single Wall Pipe Parallel InstallationDouble Wall Pipe Parallel Installation Corner Installation with Single and Double Wall PipeVenting Chimney ConnectorsDraft Chimney Installing to a Prefabricated Chimney Existing Masonry ChimneysVenting to a Masonry Chimney Venting to a Masonry Fireplace ChimneyStandard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built ChimneyMantel and Trim Protection Floor Protection Chimney Breach Fireplace Conversion with Combustible Wall Operation Combustion ProcessBuilding a Fire Do not use chemicals or fluids to start the fireBuilding and Maintaining the Fire Maintenance Gaskets Damper Ramp AdjustmentCreosote Options Outside Air optionalService Parts Part number list on followingStocked at depot #18 damper arm assembly At depot#15 Kit a #16 Kit b Stocked#19 Firebox assembly StockedThis page intentionally left blank Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifHarman TL300 Harman TL300 Page Signature of Boxer Proudly Printed On 100% Recycled Paper

TL 300 specifications

The Harman Stove Company TL 300 is an exceptional pellet stove that combines efficiency, versatility, and modern design, making it a popular choice for homeowners seeking a reliable heating solution. Its range of impressive features sets it apart from other products in the market, ensuring it meets the diverse needs of today's consumers.

One of the standout characteristics of the TL 300 is its superior heating capacity. Designed to efficiently heat areas up to 2,500 square feet, this stove is equipped with a powerful blower that optimally circulates warm air throughout the living space, maintaining comfort in even the coldest conditions. With its impressive heat output of up to 45,000 BTUs, it is capable of providing reliable warmth for large homes or open floor plans.

The TL 300 also showcases advanced technology. It features Harman's patented Smart Control system, which provides users with easy-to-use, programmable heating options. This innovative technology allows for precise temperature control, ensuring that the stove operates efficiently and effectively according to personal heating demands. Users can set their preferences for different times of the day, creating a customized heating schedule that optimizes comfort while conserving energy.

Another significant aspect of the TL 300 is its eco-friendly design. Utilizing compressed wood pellets as its fuel source, this pellet stove offers a renewable and sustainable option for heating. The automatic feed system ensures a consistent burn, enhancing efficiency and reducing the frequency of manual refueling. Furthermore, the TL 300 meets stringent EPA emissions standards, making it a cleaner alternative compared to traditional wood-burning stoves.

In terms of construction, the TL 300 boasts a durable and sleek design made from high-quality materials. The heavy-duty steel body and ceramic glass door not only enhance its longevity but also provide a contemporary aesthetic that fits seamlessly into various home decors. Additionally, the large viewing window offers an inviting ambiance, allowing users to enjoy the visual appeal of the flames.

Overall, the Harman Stove Company TL 300 is an exceptional choice for homeowners looking for an efficient, stylish, and eco-friendly heating solution. With its advanced technology, impressive heating capacity, and robust construction, it is well-suited to meet the demands of modern living while providing warmth and comfort in any home.