Desa Tech CSBPT Installation, Check GAS Type, Clearances to Combustibles Vent-Free Operation Only

Page 8

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42 inches from the front, top or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids,oilorkerosenelamps,etc.)in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your stove heater gas type is different from your house gas type, do not install heater. Call dealer where you bought heater for proper type heater.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining side and back walls.

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. DO NOT place stove directly on carpeting, vinyl tile or any combustible material other than wood. The stove must be set on a metal or wood panel extending the full width and depth of the stove for these floor coverings. Important: You must maintain minimum wall and ceiling clear- ances during installation. The minimum clearances are shown in Figure 5, page 9. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances (see Figure 5, page 9)

A.Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches.

B.Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (includes corner installations).

C.Clearances from the stove top to the ceiling should not be less than 48 inches.

8

www.desatech.com

111487-01E

Image 8 Contents
What to do if YOU Smell GAS Models CSBNT, CSBPT, CSPBNT, CSPBPT, CSPINT, CspiptTable of Contents Safety Information Provide adequate clearances around air openings Product Identification Local Codes Product Features AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingAIR for Combustion Ventilation Unpacking Ventilation Air From OutdoorsInstallation Check GAS TypeClearances to Combustibles Vent-Free Operation Only Minimum Wall and Ceiling Clearances see ,Connecting to GAS Supply Installation Items NeededFront View Top ViewPetroleum LP gas Back ViewChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceInstalling LOG SET Installing ROD and ScreenStove cavity see Figure Wall clearances as outlined onLighting Instructions For Your Safety Read Before LightingOperating Heater Cleaning Maintenance Inspecting BurnersBurner Injector Holder and Pilot AIR Inlet Hole LogsBlow air into the primary air holes on the injector holder Replace logs if broken or chipped dime-sized or largerTroubleshooting Observed Problem Possible Cause RemedyDelayed ignition burner Burner orifice clogged Clean burner see CleaningWhen burner is lit Dark residue on logs or inside Improper log placementGas leak. See Warning Statement at topSpecifications Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown Parts List Stove Body Models CSB SERIES, Cspb Series and Cspi Series Parts Centrals Warranty Information Keep this Warranty