OPERATING INSTRUCTIONS

UNDERSTANDING THE TRI-X CONTROLLER

The controller is located on the lower right-hand side of the parlor stove. It uses an advanced microprocessor that allows the owner to burn multiple fuels with the touch of a key. The TRI-X screen will display, for the user, a sequence of stove functions and any faults that may occur during operation. Each key functions with a small light (LED) that indicates stove heat transitions and running status.

ON KEY

Pressing the ON key will begin the startup sequence for the stove. Fuel will feed through the auger feed system after a brief exhaust check. This check assures the burn area is sealed and the flue gases are exiting the building. The draft fan (exhaust) will start as soon as the ON key is pressed. The fan will automatically adjust speed to match the heat requirement. The circulating blower will turn on when the stove heat level has reached 110°F. When this temperature is reached, the dial to the right of the TRI-X controller is used to adjust room blower fan speed. The TRI-X screen shows the stove progress and will come to rest on [STOVE CONTROLLED BYTEMP KEY {heat level 1 thru 6}] when the stove is heating normally.

The LED light will illuminate when the ON key is pushed and remains on during normal operation.

OFF KEY

Pressing the OFF key will cause the stove to begin the shut-down sequence. If the OFF key is pushed during normal operation, wait 30 seconds before attempting any re-light of the fire. Once the fire goes out and the stove cools down, the blowers will stop running. During a fault condition, follow the instructions on the TRI-X screen and push the OFF key until the [SELECT FUEL TYPE USE MODE KEY] screen appears.

The LED will illuminate when the OFF key is pushed and remains on when the stove is not providing heat.

MODE KEY

The type of fuel is selected by pressing the MODE key. All the currently approved fuels can be viewed when scrolling (pressing) the MODE key.

There is no LED with this key.

TEMP UP OR TEMP DOWN KEYS

Pressing the TEMP UP or the TEMP DOWN keys will adjust the amount of fuel and air being delivered to the fire pot. There are six levels of heat from which to choose. Each level has been calibrated to deliver the correct ratio of air and fuel into the fire pot for the selected fuel type.

Controller Faceplate

L

H

720038

 

Circulating Blower Dial Faceplate

Page 16

CumberlandStoveWorks.com

800-345-6007

Image 18
Contents Multi Fuel Parlor Stove Page Table of Contents Warranty Limited lifetime WarrantyREGISTRATION, Service and Maintenance LOG Ownership RecordsCumberlandStoveWorks.com Automatic Safety Features Power OutageIntroduction Burning Solid FuelsWood Pellets Specifications Glass SpecificationsMount Handle to Hopper Door Unpacking and AssemblyMount Legs Assemble ASH Shuttle RODPlug in Power Cord Mount Round Exhaust TransitionInstallation Stove PlacementFloor Protection Requirements Clearances to Combustibles Outside AIR Connection Mobile HomePellet Vent Installation VentingType of Vent Venting Installation Examples Vent Termination ClearancesOperating Instructions Understanding the TRI-X ControllerUnderstanding the Normal Heat Screens ADD Fuel KEYCorn AS Fuel Push AUX 1 to SET Starting Fire Level Startup Sequence of Events Shutdown Sequence of EventsLighting Procedure Lighting the StoveTurning the stove off Normal Care & Maintenance Daily Maintenance Weekly MaintenanceSeasonal Cleaning Troubleshooting & repair Ordering Repair PartsTroubleshooting Guide Problem Cause Too rich air/fuel mixtureProblem Cause Loss of vacuum Understanding the Fault Screens Startup Check Exhaust OFFMain Assembly Parts KEY # Description Glass Door Parts ASH PAN PartsCirculating AIR Duct Parts Exhaust Parts Auger Parts Electric Panel Parts Wiring Diagram Ardisam