Breckwell P2000 owner manual Vacuum USE, Cleaning, Blowers

Page 20

20

MAINTENANCE

VACUUM USE

If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes.

(We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27)

Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage.

CLEANING

a.Heat Exchange Tubes – Your Breckwell stove is designed with a built-in heat exchange tube cleaner. This should be used every two or three days to remove accumulated ash on the tubes, which reduces the efficiency of your unit. Insert the handle end (with hole) of the cleaning tool onto the cleaning rod (refer to figure 22). The cleaner rod is located in the grill above the stove door. Move the cleaner rod back and forth several times to clean the heat exchanger tubes. When finished be sure to leave tube cleaner at the rear of the stove.

b.Interior Chambers – Three ash doors in the firebox in the P2000 can be removed for periodic cleaning (refer to figures 23 & 25). These doors allow access to the chamber surrounding the firebox.

Periodically, you must vacuum ashes from these chambers. In some cases you will need to remove creosote, which can accumulate rapidly under certain conditions. A small wire brush can be used. It is important to remove this creosote because it is highly combustible. INSPECT BEHIND THESE CLEANING PLATES AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES. Use the small wire brush to also clean the inside of the chamber walls, above the access doors.

BLOWERS

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

Cleaning – Over a period of time, ashes or dust may collect on the blades of both the combustion blower and convection blower. Periodically the blowers should be cleaned as the ash and dust can impede performance. Creosote can also accumulate on the blades in the combustion blower. This needs to be brushed clean. The convection blower is accessed by opening the stove’s side panel. The combustion blower can be accessed by opening the stove’s right side panel. The convection blower is on the left (facing stove), and the combustion blower is on the right.

NOTE: When cleaning, be careful not to dislodge balancing clip on convection blower or to bend fan blades. Some stove owners lightly spray an anti-creosote chemical on the fire to help reduce creosote formation within the stove.

Oiling – Convection blower only. Manufacturer suggests oiling every 6 months. Refer to figure 26a & 27a for lubrication points. Use SAE 20W motor oil or turbine oil. Limit to one or two drops.

NOTE: Combustion blower uses sealed bearings and does not require oiling.

FIGURE 25

FIGURE 26a

FIGURE 26b

Image 20
Contents Luxury Series P2000 Introduction Important InformationSafety Precautions Table of Contents Installation When Outside AIR is not Used Combustion AIR SupplyVenting Rear View P2000FS Rear View P2000IHorizontally Through Wall Freestanding InstallationEquivalent Vent Length EVL Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figure Chase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home RequirementsOperation Proper FuelPRE-START-UP Check Building a FireRE-STARTING a Warm Stove Opening DoorRoom AIR FAN Breckwell Maintenance Tool Shutdown ProcedureSafety Features If Stove Runs OUT of PelletsThermostat Installation Thermostat InstallationOperating the Stove Using a Thermostat Please Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertBlowers CleaningVacuum USE Chimney Cleaning Recommended Maintenance ScheduleRemoval and Replacement of Broken Door Glass Daily Weekly Bi-Annually Annually or per TonP2000I Possible Causes Troubleshooting GuideStove Shuts OFF and the # 2 Light Flashes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide High Limit Switch Keeps Tripping Smoke Smell or Soot BUILD-UPDigital Circuit Board Timing Rates P2000Electrical Diagram Replacement Parts IGN