Breckwell P2000 If Stove Runs OUT of Pellets, Damper Control, Refueling, Shutdown Procedure

Page 16

16

OPERATION

IF STOVE RUNS OUT OF PELLETS

The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.

After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off.

To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button.

DAMPER CONTROL

The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the efficiency of your stove. Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of creosote inside your stove and chimney.

You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A “blow torch” fire can be improved by pushing the damper in a bit.

As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open. Through trial and error, you will find the best setting. Consult your dealer if you need help.

NOTE: On “1”, damper should be out approximately ¼” to ½”. If damper is out too far, it can cause the fire to go out.

REFUELING

We recommend that you not let the hopper drop below ¼ full.

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. THE HOPPER MAY BE FILLED WHILE THE STOVE IS OPERATING. DO NOT OVERFILL HOPPER.

BRECKWELL MAINTENANCE TOOL

A tool has been provided to help with the following functions:

FIGURE 20

a.Stirring pellets in hopper – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.

NOTE: To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.

b.Cleaning heat exchanger tubes – see instructions in “CLEANING”.

c.Scrape ashes from burnpot.

SHUTDOWN PROCEDURE

Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The green light will go out. The blowers will continue to operate until internal firebox temperatures have fallen to a preset level.

SAFETY FEATURES

a.Your stove is equipped with a resettable high temperature thermodisc. This disc has a reset button on its backside. This safety switch has two functions.

1.To recognize an overheat situation in the stove and shut down the fuel feed or auger system.

2.To recognize an internal control board failure and shut down the fuel feed or auger system.

NOTE: Like a circuit breaker, once tripped, the reset button will have to be pushed before restarting your stove. The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A service call may be required.

b.In case of a malfunctioning convection blower, a high-temperature thermodisk will automatically shut down the auger, preventing the stove from overheating.

NOTE: Thermodisc must be reset after this occurs.

c.If the combustion blower fails, an air pressure switch will automatically shut down the auger.

NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.

Image 16
Contents Luxury Series P2000 Introduction Important InformationSafety Precautions Table of Contents Installation When Outside AIR is not Used Combustion AIR SupplyVenting Rear View P2000FS Rear View P2000IEquivalent Vent Length EVL Freestanding InstallationHorizontally Through Wall Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figure Chase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home RequirementsOperation Proper FuelPRE-START-UP Check Building a FireRoom AIR FAN Opening DoorRE-STARTING a Warm Stove Breckwell Maintenance Tool Shutdown ProcedureSafety Features If Stove Runs OUT of PelletsOperating the Stove Using a Thermostat Thermostat InstallationThermostat Installation Please Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertVacuum USE CleaningBlowers Chimney Cleaning Recommended Maintenance ScheduleRemoval and Replacement of Broken Door Glass Daily Weekly Bi-Annually Annually or per TonP2000I Stove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide High Limit Switch Keeps Tripping Smoke Smell or Soot BUILD-UPDigital Circuit Board Timing Rates P2000Electrical Diagram Replacement Parts IGN