Breckwell P2000 owner manual Replacement Parts, Ign

Page 30

30

REPLACEMENT PARTS

Contact an Authorized Breckwell Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.

ITEM

PART #

Air Switch

C-E-200

Air Switch Hose

C-M-340-T

Auger Motor

C-E-017

Breckwell Maintenance Tool

A-TOOL-96

Burnpot

A-S-070-I

Circuit Board / Control Panel

C-E-400

Combustion Blower

A-E-027

Convection Blower

A-E-033

Door Gasket

C-G-050

Door Glass – Center

C-D-802-A

Door Glass – Side

C-D-802-B

Exhaust Adapter 3”

C-M-020

Exhaust Adapter 4”

A-4-VA

Hot Rod Igniter

C-E-IGN

Thermodisk, Proof of Fire

C-E-090-22C

Thermodisk, High Temp (resettable)

C-E-090-21-R

Door Handle - Wood

C-S-852

Damper Knob - Wood

C-S-851

Window Gasket (7’)

C-G-033

Ceramic Log Set (imitation) - Optional

A-M-2000

Zero Clearance Skirt - Optional

A-ZC-2KSKRT

Zero Clearance Legs – Optional

A-S-ZCLEGS

Image 30
Contents Luxury Series P2000 Introduction Important InformationSafety Precautions Table of Contents Installation Venting When Outside AIR is not UsedCombustion AIR Supply Rear View P2000FS Rear View P2000IFreestanding Installation Equivalent Vent Length EVLHorizontally Through Wall Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figure Chase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home RequirementsPRE-START-UP Check OperationProper Fuel Building a FireOpening Door Room AIR FANRE-STARTING a Warm Stove Safety Features Breckwell Maintenance ToolShutdown Procedure If Stove Runs OUT of PelletsThermostat Installation Operating the Stove Using a ThermostatThermostat Installation Please Read this ASH Disposal Freestanding Models MaintenanceASH Removal ASH Disposal InsertCleaning Vacuum USEBlowers Removal and Replacement of Broken Door Glass Chimney CleaningRecommended Maintenance Schedule Daily Weekly Bi-Annually Annually or per TonP2000I Troubleshooting Guide Stove Shuts OFF and the # 2 Light FlashesPossible Causes Stove Shuts OFF and the # 3 Light Flashes Smoke Smell Coming Back Into the Home Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide Digital Circuit Board Timing Rates High Limit Switch Keeps TrippingSmoke Smell or Soot BUILD-UP P2000Electrical Diagram Replacement Parts IGN