Maintenance
Maintenance
Check Heating Fluid Level
Gradual fluid evaporation can occur, therefore, check the level of heating fluid monthly.
1.Remove plug (6).
2.Place flexible object in port so that it protrudes down. Pull out to observe level.
3.Refill heating fluid as necessary. See Fill Heating Fluid, page 15, for instructions.
Check for Heating Fluid Leakage
When spray material is drained and heating fluid is full, inspect the inside of the hopper for any signs of heating fluid leakage.
Drain Heating Fluid
1.Turn off all heaters and allow heating fluid to cool for a minimum of 8 hours.
2.Place either a
NOTE: Only
37
FIG. 24: Place Pail Beneath Drain Plug
3.Use wrench to hold reducer fitting (36) secure while using another wrench to remove drain plug (37) and capture heating fluid in pail.
4.Use additional pails as necessary until all fluid is drained.
5.Install plug (37) into reducer fitting (36) after fluid is completely drained from the hopper’s (D) outer jack- eted area.