Casablanca Fan Company 59096, 55020, 59095, 59097 What to Expect with Your Installation

Page 2

What to Expect with Your Installation

If you are unfamiliar with wiring, use a qualified electrician.

30 inches

 

from blade tip to

 

nearest wall or

 

obstruction

7 feet

 

www.CasablancaFanCo.com 1.888.227.2178

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.

Must be able to secure the fan to building structure or fan-rated outlet box

You may need a

friend to help you.

Know your wiring

Ceiling angles greater than 34° will require an Angled Mounting Kit. See page 4 for details.

from bottom

edge of blade

to the floor

Assess location

1 Standard Downrod

for ceilings 8-10 feet high

2 Shorter Downrod

for fans installed close to ceiling

3 Longer Downrod

for ceilings 10 feet or higher

w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

w.3 - To reduce the risk of fire, electrical shock, or motor damage, use only Casablanca Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

CAUTIONS

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.

c.2 - Use only Casablanca replacement parts.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are to provide reasonable protection against

Check box to see

 

fan weight

Assess ceiling angle

Select a downrod length

2

harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications.

M6011-01 • 10/30/14 • © Casablanca Fan Company

Image 2
Contents Table of Contents What to Expect with Your Installation Tools Needed Mounting Options Ceiling Bracket For angled ceilings, point Opening toward peakPreparation Downrod Hand Tighten Put the wires and downrod through the canopy Do not Pick the FAN UP byWiring Assembly as shownOr common Using an orange wire connector fromHardware bag After Wall ControlBefore Canopy HolesBlades Blades sold separatelySwitch Housing Which two screw holes you choose Twist counterclockwiseConnectors Switch housing screws, found Operation Maintenance & Cleaning Reverse ButtonTroubleshooting Fan doesn’t work