Bryant manual 583B ICM AIR Flow VS. Temperature Rise Chart, Performance Data

Page 18

583B ICM AIR FLOW VS. TEMPERATURE RISE CHART

 

 

RATED GAS

AIRFLOW SETTING

CALCULATED

MIN.

MAX

MAX

UNIT

COOLING SIZE

INPUT RATE

EAST SELECT™

TEMPERATURE

TEMP

TEMP

DISCH.

 

 

(X 1000)

(SCFM)

RISE

RISE

RISE

TEMP

583B

024

40

800

36.5

20

50

175

 

 

 

 

 

 

 

 

583B

024

60

1100

40

35

65

165

 

 

 

 

 

 

 

 

583B

030

40

800

36.5

20

50

175

 

 

 

 

 

 

 

 

583B

030

60

1100

40

35

65

165

 

 

 

 

 

 

 

 

583B

036

60

1100

40

25

55

165

 

 

 

 

 

 

 

 

583B

036

90

1200

54

45

75

175

 

 

 

 

 

 

 

 

583B

042

60

1000

44

20

50

165

 

 

 

 

 

 

 

 

583B

042

90

1250

53

35

65

170

 

 

 

 

 

 

 

 

583B

048

90

1250

53

25

55

165

 

 

 

 

 

 

 

 

583B

048

115

1600

53

35

65

170

 

 

 

 

 

 

 

 

583B

048

130

1750

54

40

70

175

 

 

 

 

 

 

 

 

583B

060

90

1600

41

25

55

155

 

 

 

 

 

 

 

 

583B

060

115

1600

53

35

65

170

 

 

 

 

 

 

 

 

583B

060

130

1800

53

40

70

175

 

 

 

 

 

 

 

 

PERFORMANCE DATA (CONT)

ECONOMIZER/1-IN. FILTER PRESSURE DROP (in. wg)

UNIT 583B

PRESSURE DROP

 

 

024-036

0.20

 

 

042-060

0.25

HIGH ALTITUDE COMPENSATION

NATURAL GAS ONLY

ORIFICE CONVERSION — 3.5 in. wc

MANIFOLD PRESSURE*

ALTITUDE (ft)

INPUT

OUTPUT

ORIFICE

(Btuh)

(Btuh)

NUMBER†

 

 

 

 

 

 

40,000

31,000

#44

 

 

 

 

 

60,000

46,000

#38

0-2000

 

 

 

90,000

70,000

#38

 

 

 

 

 

115,000

92,000

#33

 

 

 

 

 

130,000

103,000

#31

 

 

 

 

 

32,075

24,858

#48

 

 

 

 

 

48,547

37,219

#42

2001-6000

 

 

 

72,820

56,638

#42

 

 

 

 

 

90,094

72,075

#37

 

 

 

 

 

102,630

81,315

#34

 

 

 

 

LIQUID PROPANE ONLY

ORIFICE CONVERSION — 3.5 in. wc

MANIFOLD PRESSURE*

ALTITUDE (ft)

INPUT

OUTPUT

ORIFICE

(Btuh)

(Btuh)

NUMBER†

 

 

 

 

 

 

40,000

31,000

#50

 

 

 

 

 

57,000

43,720

#46

0-2000

 

 

 

85,500

66,520

#46

 

 

 

 

 

115,000

92,000

#42

 

 

 

 

 

127,000

100,580

#41

 

 

 

 

 

33,834

26,221

#52

 

 

 

 

 

49,238

37,766

#48

2001-6000

 

 

 

73,856

57,461

#48

 

 

 

 

 

94,571

75,657

#44

 

 

 

 

 

101,284

80,214

#43

 

 

 

 

*As the height above sea level increases, there is less oxygen per cubic ft of air. Therefore, heat input rate should be reduced at higher altitudes.

† Orifices available through your Bryant distributor.

583B ICM FIOP WET COIL PRESSURE DROP

UNIT

 

 

 

 

 

 

 

 

 

STANDARD CFM

 

 

 

 

 

 

 

 

 

 

SIZE

600

700

800

 

900

 

1000

1100

1200

 

1300

 

1400

 

1500

1600

 

1700

 

1800

1900

 

2000

2100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

0.005

0.007

0.010

 

0.012

 

0.015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

0.007

0.010

 

0.012

 

0.015

0.018

0.021

 

0.024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

 

0.019

 

0.023

0.027

0.032

 

0.037

 

0.042

 

0.047

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

 

 

0.014

0.017

0.020

 

0.024

 

0.027

 

0.031

0.035

 

0.039

 

0.043

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

 

0.027

 

0.032

 

0.036

 

0.041

0.046

 

0.052

 

0.057

0.063

 

0.068

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

 

 

 

 

0.029

0.032

 

0.036

 

0.040

0.045

 

0.049

0.053

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— 18—

Image 18
Contents Efficient Operation FEATURES/BENEFITSUnit 583B DURABLE, Dependable ComponentsModel Number Nomenclature Table of Contents ARI* Capacities Cooling Capacities and EfficienciesRange F ARI* CapacitiesHeating Capacities and Efficiencies UnitPhysical Data Unit Size 583BPhysical Data Options and Accessories Factory-installed optionsEconomizer Base Unit Dimensions 583B024-036 Electrical Unit Weight Unit Height Center of GravityCharacteristics Base Unit Dimensions 583B042-060 Roof Curb for Small Cabinet Accessory DimensionsRoof Curb Dimensions Side View Unit Size ODS Order NumberSelect Unit That Corresponds to Power Source Available 583B Corner WeightsSelection Procedure with Example II Select Unit Based on Required Cooling Capacity583B024 Cooling Performance Table SHC583B030 Cooling Performance Table 583B036 Cooling Performance Table Performance DataCooling Capacities 583B042 Cooling Performance Table583B048 Cooling Performance Table 583B060 Cooling Performance TablePSC 583B Standard UNIT-WET Coil AIR Flow Delivery Filter Size CFM583B Heating ICM AIRFLOW-SMALL Cabinet 583B Cooling DRY Coil ICM AIRFLOW-SMALL Cabinet583B Cooling DRY Coil ICM AIRFLOW-LARGE Cabinet 583B Heating ICM AIRFLOW-LARGE CabinetHigh Altitude Compensation 583B ICM AIR Flow VS. Temperature Rise ChartPerformance Data 583B ICM Fiop WET Coil Pressure DropTypical Piping and Wiring Application Data Minimum cooling airflow The minimum coolingElectrical Data 583B Standard Electrical Data 583B with ICM Fiop Electrical DataTypical Wiring SCHEMATIC-208/230-1-60 Shown C99076Typical Wiring SCHEMATIC-208/230-3-60 Shown C99077Typical Wiring SCHEMATIC-460-3-60 Shown ICM Fiop Wiring SCHEMATIC-208/230-1-60 Controls Operating SequenceGuide Specifications Part 1 GeneralPart 2 Products Guide Specifications
Related manuals
Manual 30 pages 21.04 Kb Manual 30 pages 37.07 Kb

583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.