3. To install the housing in the ceiling, position it between the joists and extend the brackets to the adjacent joists. Mark the screw locations (at the top of the keyhole on each
bracket) on the joists.
Note: make sure to allowCeiling
the appropriate depth for | Figure 4 | |
the particular ceiling type. | ||
|
The bottom edge of the
housing should be flush with the ceiling. (Figure 4)
4.Remove the housing and drive the screws part way into the joists at the marked locations.
5.Mount the housing using the screws in the joists and then secure them tightly. Make all the electrical connections in the electrical box, per the wiring diagram, and attach the electrical box cover. Attach the discharge duct tightly onto
the fan outlet.
Note: In order for the fan to operate efficiently, keep the discharge duct as straight as possible.
6.To complete the installation, install the lamps (if applicable) and mount the grille.
RECOMMENDED MAINTENANCE
1.Turn the power off and lock it out prior to servicing or cleaning.
2.To clean the grille, first remove it from the fan then use a soft brush and clean water to remove the dirt. If the dirt is not easily removed, wash with a neutral detergent.
3.In order to remove the impeller and housing for maintenance, first remove the light, night light and reflector (if applicable). Then unplug the electrical connection and remove the 4 screws that secure the fan assembly to the housing. To
clean the impeller and housing, remove the motor and then wash with water or a neutral detergent, as required.
Note: Keep all electrical components away from water. Do not use corrosive chemicals or water in excess of 60C (140F) to clean plastic parts.
WIRING PROCEDURE
Refer to the wiring diagram.
FAN SPECIFICATIONS
MODEL | VOLTAGE | FREQUENCY | POWER CONSUMPTION (W) | SPEED | AIRFLOW | ||
|
|
| |||||
| (V) | (HZ) | MOTOR | PL LAMP | NIGHT LIGHT | (RPM) | (CFM) |
|
|
|
|
|
|
|
|
TBF90 | 120 | 60 | 25 | 750/1050 | 60/90 | ||
|
|
|
|
|
|
|
|
TBF120 | 120 | 60 | 40 | 775/1050 | 90/120 | ||
|
|
|
|
|
|
|
|
TBFS90L | 120 | 60 | 25 | 26 | 4 | 750/1050 | 60/90 |
|
|
|
|
|
|
|
|
TBFS120L | 120 | 60 | 40 | 26 | 4 | 775/1050 | 90/120 |
|
|
|
|
|
|
|
|
TBFR90L | 120 | 60 | 25 | 26 | 4 | 750/1050 | 60/90 |
|
|
|
|
|
|
|
|
TBFR120L | 120 | 60 | 40 | 26 | 4 | 775/1050 | 90/120 |
|
|
|
|
|
|
|
|
CONDENSED WARRANTY
All warranty claims must be processed through point of purchase. All warranty repair work must be authorized by Vendor.
AeroFan Superior Bathroom Fans are warranted against defects in material and workmanship for a period of three years from date of purchase. Warranty does not include consumable components such as lamps. All other products are warranted for a period of one year from date of purchase.
WARRANTY DOES NOT APPLY TO:
•Shipping damage, either concealed or visible. Claims must be filed with the carrier.
•Damage caused by improper installation, wiring, or incorrect electrical voltage.
•Materials that have been modified, altered, or disassembled.
•Damage caused by corrosion, erosion, abrasion or severe temperature.
•Materials that have had the identification labels removed or altered.
•Materials that have been subjected to abuse, misuse, abnormal usage, or accident.
•Materials that have not been properly maintained.
No other warranties, expressed, implied or written shall apply to this product. Vendor will not be responsible for any consequential or incidental damages, loss of property, revenues or profit, cost of removal, installation, or reinstallation, personal damage or loss of life, or for any breach of warranty, regardless of how caused.
For a complete description of our Limited Warranty conditions, visit www.continentalfan.com.
USA | www.continentalfan.com |
| Canada | www.aeroflo.com |
Continental Fan Manufacturing Inc. | Aeroflo Inc. |
| ||
203 Eggert Rd. |
|
| ||
Buffalo, NY 14215 |
|
| Mississauga, ON | L4Z 3E3 |
Tel: | Toll: | Tel: | Toll: |
AEROFAN