Avalon Stoves 700 B-VENT Features and Specifications, Installation Options Features, Dimensions

Models: 700 B-VENT

1 34
Download 34 pages 56.73 Kb
Page 5
Image 5

 

 

 

FEATURES AND SPECIFICATIONS PAGE 5

 

 

 

 

 

 

 

Installation Options:

Features:

 

 

 

 

 

 

¥

Works During Power Outages

 

 

 

¥

Freestanding

 

(millivolt system)

 

 

 

 

¥

High Efficiency; Up to 80% for Natural Gas,

 

 

 

 

 

 

¥

Masonry Fireplace Insert

 

82% for LP (Steady State)

 

 

 

¥

Optional Thermostat or Remote Control

 

 

¥

Zero-Clearance (Metal)

¥

Realistic "Wood Fire" Look

 

 

 

¥

Convenient Operating Controls

 

 

 

 

Fireplace Insert

¥

Variable-Rate Heat Output

 

 

 

 

 

¥

Quiet Blower for Effective Heat Distribution

 

 

 

 

¥

Low Maintenance

 

 

 

 

Heating Specifications:

 

 

 

 

 

 

 

Approximate Heating Capacity (in square feet)*

600 - 1600

 

 

 

AFUE (Annual Fuel Utilization Efficiency)

 

68 %

 

 

 

 

 

 

Natural Gas

LP (Propane)

 

 

High Burn Input Rate (In BTU's)

 

40,000

 

38,000

 

 

 

Low Burn Input Rate (In BTU's)

 

23,000

 

20,000

 

 

 

Efficiency**

 

80%

 

82%

 

*Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.

**Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system. To measure the net BTU's, multiply the BTU input by the efficiency percentage (80% for natural gas, 82% for LP).

Dimensions

The base of the

Measure Clearances

Weight: 175 Lbs.

The base of the starter section

from the Upper Top

is 2" below the upper top.

starter section

 

 

 

is 2" below the

 

 

 

upper top.

 

 

 

 

23-3/4"

 

 

 

 

8" Panels: 28"*

20-1/8"

 

 

 

 

4-1/2"

10" Panels: 30"*

4-1/2"

 

12" Panels: 32"*

 

18-5/8"

 

 

23-3/4"

 

 

 

 

Pedestal: 31-1/2"

 

 

 

Brass, Cast Legs: 28"

 

 

 

Black Legs: 26-5/8"

8" Panels: 40"*

 

 

 

 

 

 

10" Panels: 44"*

13"*

 

 

12" Panels: 48"*

 

 

 

 

 

* Includes

5-3/4"*

 

 

 

Fuel:

Emissions:

Electrical Specifications:

The heater is designed either for natural gas or for propane (but not for both). Check the sticker on the top of the gas control valve.

This unit has passed the ANSI emission standards for vented room heaters as tested by OMNI Environmental Services, Inc.

115 Volts, 1.3 Amps, 60 Hz (150 watts on high)

Page 5
Image 5
Avalon Stoves 700 B-VENT Features and Specifications, Installation Options Features, Heating Specifications, Dimensions