LISTING INFORMATION PAGE 25

The safety label can be found on the rear panel. A copy is shown below.

Tested &

 

Beaverton,

700

 

Listed by

 

OR. USA

TM B-VENT

 

Listed Gas-Fired Vented Room Heater

Tested to ANSI Z21.11.1-1991, ANSI Z21.11.1a-1993, CAN/CGA 2.1M88, CAN/CGA 2.17M91

By OMNI Environmental Services (Report #028-S-09-5, January 1996)

Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 in USA, CAN B149 in Canada, and the requirements listed in the accompanying owner's manual.

Electrical connections and grounding must be installed in accordance with local codes, if any; if not, follow ANSI/NFPA 70 in USA or CSAC 2.21 in Canada.

Controls: Robertshaw Model 7000MVRB-5-LC

This room heater is equipped at the factory for use with natural gas, if conversion to propane (LP) fuel is desired, the optional factory conversion kit #98900745 must be used.

Input and Orifice Specifications:

L.P.

N.G.

Maximum Input Rating (BTU/Hr)

38,000

40,000

Minimum Input Rating (BTU/Hr)

20,000

23,000

Front Burner Orifice (DMS)

#49

#31

Pressure Specifications:

L.P.

N.G.

 

 

 

Manifold Pressure HI Setting (in W.C.)

10Ó

3.5Ó

Manifold Pressure LO Setting (in W.C.)

2.7Ó

1.0Ó

Minimum Inlet Pressure (in W.C.)

11Ó

5.5Ó

Minimum Clearance to Combustibles

 

 

Unit to Sidewall

10

"

Unit to Backwall

4

"

Unit to Cornerwall

4

"

Side Facing to Unit

8

"

Top Facing to Unit

8

"

Alcove Minimum Width

44

"

Alcove Minimum Height

58

"

Alcove Maximum Depth

45

"

Front of Unit

36

"

Mantle Height Above Unit

17.5

"

Hearth Extension Front

0

"

Hearth Extension Sides

0

"

Use only with ÒBÓ vent listed chimney

Blower Electrical Rating: 115 Volts, 1.5 Amps, 60 Hz.

FAN TYPE VENTED CIRCULATOR

WARNING:

Operation of this heater when not connected to a properly installed and maintained venting system of tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the owner's manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

Risk of electrical shock. Disconnect power before servicing unit.

This room heater needs fresh air for safe operation and must be installed with provisions for adequate combustion and ventilation air. See ownerÕs installation and operating instructions.

Manufacture

 

 

1997

 

 

 

Jan.

 

 

 

Apr.

 

 

 

Jul.

 

 

 

Oct.

 

Date:

 

 

1998

 

 

 

Feb.

 

 

 

May

 

 

 

Aug.

 

 

 

Nov.

10850 117th Pl. N.E. Kirkland, WA 98033

 

 

 

 

 

 

 

 

1999

 

 

 

Mar.

 

 

 

Jun.

 

 

 

Sep.

 

 

 

Dec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT REMOVE THIS LABEL

 

 

 

MADE IN U.S.A.

Page 25