B-13160-A2-GB21-50 January 1997

Technical Specifications

Overview B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The technical specifications for the standalone
DSU/CSUs are listed in Table B-1. The technical
specifications for the carrier-mounted DSU/CSUs are
listed in Appendix B of the ACCULINK 3151 CSU and
3161 DSU/CSU General Information Guide.
Table B-1
(1 of 2)
Models 3160/3164/3165 DSU/CSUs Technical Specifications
Specifications Criteria
POWER REQUIREMENTS
Typical:
AC Power Module
Optional:
+24 Vdc
–48 Vdc
–48 Vdc Redundant
Refer to the labeling on the ac power module for input requirements
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to –60 Vdc, 0.25A
–38 Vdc to –60 Vdc, 0.25A
POWER CONSUMPTION AND
DISSIPATION 16.0 watts, 55.0 Btu per hour at 115 volts (ac power); 12.0 watts, 41 Btu per hour
at +24 and –48 Vdc (dc power)
DTE DROP/INSERT
(DSX-1) INTERFACE
(Models 3160/3164)
Physical Interface
Framing Format
Coding Format
DTE Line Equalization
Send AIS
DB15 socket
D4, ESF
AMI, B8ZS
5 selectable ranges from 0 to 655 feet (0 to 196.5 meters)
Selectable
B