Technical Specifications B

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1

Overview

The technical specifications for the standalone DSU/CSUs are listed in Table B-1. The technical specifications for the carrier-mounted DSU/CSUs are listed in Appendix B of the ACCULINK 3151 CSU and 3161 DSU/CSU General Information Guide.

Table B-1

(1 of 2)

Models 3160/3164/3165 DSU/CSUs Technical Specifications

Specifications

Criteria

 

 

POWER REQUIREMENTS

 

Typical:

 

AC Power Module

Refer to the labeling on the ac power module for input requirements

Optional:

 

+24 Vdc

+20 Vdc to +32 Vdc, 0.50A

±48 Vdc

±38 Vdc to ±60 Vdc, 0.25A

±48 Vdc Redundant

±38 Vdc to ±60 Vdc, 0.25A

 

 

POWER CONSUMPTION AND

16.0 watts, 55.0 Btu per hour at 115 volts (ac power); 12.0 watts, 41 Btu per hour

DISSIPATION

at +24 and ±48 Vdc (dc power)

 

 

DTE DROP/INSERT

 

(DSX-1) INTERFACE

 

(Models 3160/3164)

 

Physical Interface

DB15 socket

Framing Format

D4, ESF

Coding Format

AMI, B8ZS

DTE Line Equalization

5 selectable ranges from 0 to 655 feet (0 to 196.5 meters)

Send AIS

Selectable

 

 

3160-A2-GB21-50

January 1997

B-1

Page 104
Image 104
Paradyne 3160-A2-GB21-50 manual Technical Specifications B, Models 3160/3164